E-mail
2336539452@qq.com
-
Phone
15221225095
-
Address
Huangdu Industrial Park, Jiading District, Shanghai
Shanghai Shuangjia Valve Co., Ltd
2336539452@qq.com
15221225095
Huangdu Industrial Park, Jiading District, Shanghai
one、Steam electric temperature control valveProduct Overview
Steam electric temperature control valve(Electric temperature control valve), composed of control valve, actuator, sensor, capillary tube and other components. It is divided into heating type and cooling type according to its purpose.Electric temperature control valve(Suitable for larger diameters and thermal oil control), this valve only requires a regular 220V power supply and utilizes the energy of the regulated medium to directly automatically adjust and control the temperature of steam, hot water, hot oil, gas and other media. It can also be used to prevent overheating or heat exchange,Steam electric temperature control valveThe structure is simple, the operation is convenient, the temperature range is wide, the response time is fast, the sealing performance is reliable, and it can be adjusted freely during operation. Therefore, it is widely used in hot water supply for chemical, petroleum, food, textile, hotel and restaurant departments.Steam electric temperature control valve, principle of temperature controlled steam valve
Steam electric temperature control valveMainly suitable for temperature control of liquids, gases, and vapors in various cooling systems. When the temperature of the controlled medium increases, the control valve closes (heating type); When the temperature of the controlled medium increases, the control valve opens (cooling type). The main features are as follows:
1. High control accuracy, stable operation, safe and reliable.
2. The temperature sensitive liquid expands uniformly and is controlled by proportional adjustment.
3. The temperature setting operation is simple and easy to adjust.
4. Small in size, lightweight, and easy to install.
two、Steam electric temperature control valveworking principle
Electric temperature control valveIt consists of control valves, electric actuators, temperature sensors, and temperature regulators. According to user needs, there are two types of structures: heating and cooling. Heating typeSelf operated electric control temperature regulating valveStructure and principle: Before operation, the main valve core is in a semi open position, and the sensor is in a natural state. Connect the power supply and fully open the main valve core. The medium flows into the main valve body in the direction of the arrow and heats the thermal storage tank through the valve core. When the temperature rises to the corresponding set value, the sensor generates a corresponding linear signal input to the integrated actuator, which then drives the valve stem and valve core to produce displacement, and closes the main valve core to stop heating. When the temperature is lower than the set value, the sensor generates a linear signal input to the integrated actuator, which drives the valve core to gradually open, causing the medium to flow into the heat storage tank according to parabolic characteristics and heat up until the set value. In this way, the controlled medium is always controlled within the set temperature range, thus achieving the purpose of temperature control. Note: Commonly referred to as heating type and cooling type. This can be achieved by simply replacing the valve core structure in this valve.Steam electric temperature control valve, principle of temperature controlled steam valve
three、Steam electric temperature control valveMain technical parameters
● Valve body
| Valve body form | Direct Casting Ball Valve |
| Nominal Diameter | DN15~200mm |
| Nominal Pressure | PN1.6、2.5、4.0、6.4MPa |
| Flange Standard | GB/T9113、 JB/T79 |
| connection type | Flanges (FF RF RTJ), welding (SW BW), threads (applicable for 1 inch or less) |
| Valve cover form | Standard type -17~+230 ℃, high temperature type+230~+450 ℃ |
| Cover type | Bolt compression type |
| sealing packing | V-shaped PTFE packing, PTFE impregnated asbestos packing, asbestos textile packing, graphite packing |
Valve internals
| Valve core form | Single seat valve core |
| flow characteristics | Straightness |
● Execution mechanism, sensor, capillary tube
| Model of actuator | 3810 series, PSL series |
| Main technical parameters | Power supply voltage: 220V/50Hz, input signal: 4-20mA or 1-5V · DC, output signal: 4-20mA · DC |
| Protection level: equivalent to IP55, explosion-proof mark: Exd Ⅱ BT4, manual operation function: handle | |
| Environmental temperature: -25~+70 ℃, environmental humidity: ≤ 95% | |
| Warm pack and capillary tube materials | H62、1Cr18Ni9Ti |
| capillary length | 3 meters, 5 meters, 10 meters |
| Temperature control range | 0~250℃ |
| Set value deviation | ±2℃ |
four、Steam electric temperature control valveMain component materials and internal structure diagram
| 1 | valve body | WCB | CF8 | CF8M | CF3M |
| 2 | valve seat | 304 | 304 | 316 | 316L |
| 3 | shim | PTFE/metal graphite gasket | |||
| 4 | valve core | 304 | 304 | 316 | 316L |
| 5 | guide bushing | 304 | 304 | 316 | 316L |
| 6 | valve cover | WCB | CF8 | CF8M | CF3M |
| 7 | valve stem | 304 | 304 | 316 | 316L |
| 8 | filler | PTFE/flexible graphite | |||
| 9 | spring | 65Mn | |||
| 10 | nut | 304 | 304 | 316 | 316L |
five、Steam electric temperature control valveRated travel and flow capacity, leakage standards
| Nominal diameter (mm) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |
| Flow capacity (m3/h) | 7 | 10 | 16 | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | |
| Rated stroke (mm) | 6 | 8 | 10 | 14 | 20 | 30 | 30 | 40 | ||||
| Adjustment accuracy (℃) | ± 1 ~ ± 5 | |||||||||||
| Using media | Steam, water, oil, gas | |||||||||||
| allow | hard seal | 10-4X valve rated capacity | ||||||||||
| soft seal | 0 | |||||||||||
six、Steam electric temperature control valveMain appearance and connection dimensions
| Nominal diameter DN (mm) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |
| L | PN16/25 | 181 | 184 | 200 | 222 | 254 | 276 | 298 | 352 | 410 | 451 | 600 |
| PN40 | 194 | 197 | 200 | 235 | 267 | 292 | 317 | 368 | 425 | 473 | 610 | |
| PN64 | 206 | 200 | 210 | 251 | 286 | 311 | 337 | 394 | 440 | 508 | 650 | |
| H | PN16/25 | 52.5 | 57.5 | 75 | 75 | 85.5 | 92.5 | 100 | 110 | 142.5 | 158 | 170 |
| PN40 | 52.5 | 57.5 | 75 | 75 | 82.5 | 92.5 | 100 | 117.5 | 150 | 167.5 | 187.5 | |
| PN64 | 65 | 40 | 85 | 85 | 90 | 102.5 | 107.5 | 125 | 172.5 | 195 | 207.5 | |
| H1 | 132 | 132 | 158 | 170 | 179 | 214 | 221 | 234 | 270 | 294 | 331 | |
| H2 | CHL | 465 | 465 | 465 | 465 | 465 | 560 | 560 | 560 | 560 | 560 | 788 |
| 3810 | 373 | 373 | 495 | 495 | 495 | 700 | 700 | 700 | 725 | 725 | 725 | |
| D | 177 | 177 | 177 | 177 | 177 | 182 | 182 | 182 | 182 | 182 | 218 | |
| R | 225 | 225 | 225 | 225 | 225 | 257 | 257 | 257 | 310 | 310 | 310 | |
Note: The dimensions in the table are without standard attachment data. Due to possible changes in product improvement technology innovation parameters, please consult the company's technical department for new data.