The ABT-60/ABT-100 two beam frequency conversion version infrared beam adopts 4-stage frequency conversion technology, which is suitable for long-distance and stacked installation environments, effectively solving the industry problem of mutual interference between infrared beams during installation under complex conditions.
ABT-60 / ABT-100Two beam variable frequency infrared beamProduct Features
Adopting 4-stage frequency conversion technology, it is suitable for long-distance and stacked installation environments, effectively solving the industry problem of mutual interference of infrared radiation during installation under complex conditions.
Double digital tubes accurately display signal strength, which is conducive to capturing and displaying small signals, and can prevent large signals from saturating too quickly. Debugging is intuitive and convenient.
The alarm triggering time can be adjusted (50ms, 100ms, 300ms, and 700ms), and can be adjusted according to the needs of different environments and scenarios.
Infrared signal secondary processing technology ensures a power margin of over 90%, making it more adept at dealing with adverse weather conditions such as wind, rain, frost, snow, fog, tide, and direct sunlight.
The pure digital CPU control circuit controls the transmission and reception through the CPU, with high-power infrared transmission and reception tubes, low-power digital frequency conversion processing technology, reducing false alarms and eliminating missed alarms.
Auxiliary light calibration transforms the traditional bidirectional calibration of the infrared beam from a collision probability based transmitter and receiver to a traceable unidirectional calibration, making the efficiency of infrared beam calibration more efficient.
Wide voltage design, truly solving the problem of line voltage reduction, with power supply voltage values between AC/DC12V-24V, making it convenient for centralized power supply.
Multiple applications of C-type relay output.
Anti tamper switch, opens when the casing is removed.
ABT-60 / ABT-100Two beam variable frequency infrared beamTechnical Specifications
Model: ABT-60/ABT-100
Outdoor warning distance: 60m/100m
Indoor warning distance: 180m/300m
Maximum communication distance: 350m/600m
Current consumption: 75mA max/85mA max
Detection method: simultaneous interruption of two beams of light
Interruption time: 50ms/100ms/300ms/700ms adjustable (toggle switch selection)
Power supply voltage: DC9-30V/AC9-20V
Beam frequency: 4 options (transmitter and receiver must be set to the same frequency)
Alarm cycle: ≥ 1.5s
Power supply and voltage: DC11-18V, current 50-90mA (Max)
Alarm output: Relay contact output 1C, contact capacity AC/DC30V 1A max
Anti disassembly output: normally closed, opens when the casing is removed
Protection level: IP65
Working temperature: -25 ℃~55 ℃
Environmental humidity: 95%
Correction angle: Horizontal 180 ° (± 90 °), Vertical 20 ° (± 10 °)
Installation location: indoor/outdoor, wall/pole installation
Weight (transmitter+receiver): 1000g
Size: 75 × 80 × 212mm
attachment
U-shaped bracket: 2 pieces, 70.4mm * 37.5mm * 21.5mm, thickness 1.5mm, stainless steel
Installation screws for pole: 4, PM4*25mm