Welcome Customer !

Membership

Help

Shanghai Hengqi Instrument Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Shanghai Hengqi Instrument Co., Ltd

  • E-mail

    info@hq17.com

  • Phone

  • Address

    4th Floor, Building A, No. 1, Lane 658, Jinzhong Road, Changning District, Shanghai

Contact Now

Viscosity standard liquid

NegotiableUpdate on 09/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Introduction: Reagecon Viscosity Standard Liquid

Product Details

Viscosity standard liquid
Characteristics of Reagecon viscosity standard solution
Viscosity standard liquid
Viscometer is a physical property analysis instrument used to measure the viscosity of fluids. Viscosity is a physical property of fluid substances that reflects the internal friction between molecules when the fluid is subjected to external forces. The viscosity of a substance is closely related to its chemical composition. In industrial production and scientific research, the composition or quality of substances is often monitored by measuring viscosity. In the production process of polymer materials, the application of a viscometer can monitor the viscosity of the synthesized reaction products and automatically control the reaction endpoint. Viscosity measurement is required for other production processes such as oil cracking, lubricant blending, automatic control of certain foods and drugs, monitoring of crude oil pipeline transportation, quality inspection of various petroleum products and paints, etc.
Shanghai Hengqi Instrument provides viscosity standard solution, which can be used for calibration, control, validation, determination or method validation of kinematic and dynamic viscosity measuring instruments (manual and automatic). All products can be traced back to the temperature range of ITS-90 and the commonly accepted standard value for water viscosity at 20 ° C, which is specified as 1.0034mm2/s (cSt) by ISO3666.
Product advantages:
1. Manufacturing and certification of Ubbelohde standard viscometer according to ASTM D2162. This is the main method for internationally recognized viscosity standard liquid certification.
2. Each standard solution is certified for its kinematic viscosity (mm2/s, CST), dynamic viscosity (CP), and density (g/ml) within a certain temperature range.
3. Long shelf life.
4. All standard samples conform to Newtonian fluid characteristics.
Viscosity standard solution specified in CST
Item Number English product name Chinese name description Specifications
REVIS-N.4 Viscosity Standards(cSt) reads Viscosity standard liquid 0.47@20 °C, 0.45@25 °C, 0.41@37.78 °C, 0.4@40 °C 500ml
REVIS-N.8 Viscosity Standards(cSt) reads Viscosity standard liquid 0.74@20 °C, 0.7@25 °C, 0.61@37.78 °C, 0.6@40 °C 500ml
REVIS-N1.0 Viscosity Standards(cSt) reads Viscosity standard liquid 1.3@20 °C, 1.2@25 °C, 1@37.78°C, 0.97@40 °C, 0.87@50 °C 500ml
REVIS-N10 Viscosity Standards(cSt) reads; Viscosity standard liquid 20@20 °C, 16@25 °C, 11@37.78 °C, 10@40 °C, 7.5@50 °C 500ml
REVIS-N100 Viscosity Standards(cSt) reads; Viscosity standard liquid 320@20 °C, 230@25 °C, 110@37.78 °C, 98@40 °C, 61@50 °C 500ml
REVIS-N1000 Viscosity Standards(cSt) reads; Viscosity standard liquid 3300@20 °C, 2300@25 °C, 1100@37.78 °C, 940@40 °C, 560@50 °C 500ml
REVIS-N10200 Viscosity Standards(cSt) reads; Viscosity standard liquid 58000@20 °C, 36000@25 °C, 10, 000@40 °C, 4900@50 °C 500ml
REVIS-N14 Viscosity Standards(cSt) reads; Viscosity standard liquid 30@20 °C, 24@25 °C, 15@37.78 °C, 14@40 °C, 10@50 °C 500ml
REVIS-N140 Viscosity Standards(cSt) reads; Viscosity standard liquid 400@20 °C, 300@25 °C, 160@37.78 °C, 140@40 °C, 90@50 °C 500ml
REVIS-N1400 Viscosity Standards(cSt) reads; Viscosity standard liquid 4900@20 °C, 3500@25 °C, 1600@37.78 °C, 1400@40 °C, 830@50 °C 500ml
REVIS-N15000 Viscosity Standards(cSt) reads; Viscosity standard liquid 77000@20 °C, 47000@25 °C, 13000@40 °C, 6100@50 °C 500ml
REVIS-N18000 Viscosity Standards(cSt) reads; Viscosity standard liquid 10, 0000@20 °C, 64000@25 °C, 18000@40 °C, 8500@50 °C 500ml
REVIS-N2 Viscosity Standards(cSt) reads; Viscosity standard liquid 2.9@20 °C, 2.6@25 °C, 2.1@37.78 °C, 2@40°C, 1.7@50 °C 500ml
REVIS-N250 Viscosity Standards(cSt) reads; Viscosity standard liquid 790@20 °C, 580@25 °C, 280@37.78 °C, 250@40 °C, 160@50 °C 500ml
REVIS-N2500 Viscosity Standards(cSt) reads; Viscosity standard liquid 7900@20 °C, 5800@25 °C, 2800@37.78 °C, 2500@40 °C, 1500@50 °C 500ml
REVIS-N26 Viscosity Standards(cSt) reads; Viscosity standard liquid 59@20 °C, 47@25 °C, 27@37.78 °C, 25@40 °C, 18@50 °C 500ml
REVIS-N35 Viscosity Standards(cSt) reads; Viscosity standard liquid 88@20 °C, 66@25 °C, 35@37.78 °C, 32@40 °C, 21@50 °C 500ml
REVIS-N350 Viscosity Standards(cSt) reads; Viscosity standard liquid 980@20 °C, 710@25 °C, 340@37.78 °C, 310@40 °C, 190@50 °C 500ml
REVIS-N4 Viscosity Standards(cSt) reads; Viscosity standard liquid 6.7@20 °C, 5.8@25 °C, 4.2@37.78 °C, 4@40°C, 3.2@50 °C 500ml
REVIS-N4000 Viscosity Standards(cSt) reads; Viscosity standard liquid 19000@20 °C, 12000@25 °C, 4000@37.78 °C, 3400@40 °C, 1700@50 °C 500ml
REVIS-N415 Viscosity Standards(cSt) reads; Viscosity standard liquid 1400@20 °C, 1000@25 °C, 470@37.78 °C, 410@40 °C, 250@50 °C 500ml
REVIS-N44 Viscosity Standards(cSt) reads; Viscosity standard liquid 110@20 °C, 87@25 °C, 48@37.78 °C, 44@40 °C, 30@50 °C 500ml
REVIS-N5100 Viscosity Standards(cSt) reads; Viscosity standard liquid 28000@20 °C, 17000@25 °C, 6000@37.78 °C, 5100@40 °C, 2500@50 °C 500ml
REVIS-N7.5 Viscosity Standards(cSt) reads; Viscosity standard liquid 14@20 °C, 12@25 °C, 8@37.78°C, 7.5@40 °C, 5.8@50 °C 500ml
REVIS-N75 Viscosity Standards(cSt) reads; Viscosity standard liquid 210@20 °C, 160@25 °C, 83@37.78 °C, 75@40 °C, 50@50 °C 500ml
REVIS-N750 Viscosity Standards(cSt) reads; Viscosity standard liquid 2600@20 °C, 1800@25 °C, 850@37.78 °C, 750@40 °C, 450@50 °C 500ml
REVIS-S20 Viscosity Standards(cSt) reads; Viscosity standard liquid 43@20 °C, 34@25 °C, 20@37.78 °C, 18@40 °C, 13@50 °C 500ml
REVIS-S200 Viscosity Standards(cSt) reads; Viscosity standard liquid 550@20 °C, 400@25 °C, 200@37.78 °C, 180@40 °C, 110@50 °C 500ml
REVIS-S2000 Viscosity Standards(cSt) reads; Viscosity standard liquid 8400@20 °C, 5300@25 °C, 1900@37.78 °C, 1600@40 °C, 810@50 °C 500ml
REVIS-S3 Viscosity Standards(cSt) reads; Viscosity standard liquid 4.4@20 °C, 3.9@25 °C, 3@37.78°C, 2.9@40 °C, 2.4@50 °C 500ml
REVIS-S30000 Viscosity Standards(cSt) reads; Viscosity standard liquid 79000@25 °C, 28000@37.78 °C, 23000@40 °C, 11000@50 °C 500ml
REVIS-S6 Viscosity Standards(cSt) reads; Viscosity standard liquid 10@20 °C, 8.7@25 °C, 6@37.78°C, 5.7@40 °C, 4.4@50 °C 500ml
REVIS-S60 Viscosity Standards(cSt) reads; Viscosity standard liquid 160@20 °C, 120@25 °C, 60@37.78 °C, 54@40 °C, 35@50 °C 500ml
REVIS-S600 Viscosity Standards(cSt) reads; Viscosity standard liquid 1800@20 °C, 1300@25 °C, 590@37.78 °C, 520@40 °C, 310@50 °C 500ml
REVIS-S8000 Viscosity Standards(cSt) reads; Viscosity standard liquid 41000@20 °C, 25000@25 °C, 8000@37.78 °C, 6700@40 °C, 3200@50 °C 500ml