WQD submersible pump manufacturer

NegotiableUpdate on 02/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The WQD submersible pump consists of three parts: water pump, seal, and electric motor. The electric pump is equipped with a protective device. The electric motor is located at the upper part of the electric pump and is a single-phase or three-phase asynchronous motor; The water pump is located at the lower part of the electric motor, with a centrifugal impeller and volute structure; Double end mechanical seals are used between the water pump and the electric motor, and "O" - shaped oil resistant rubber seals are used for static sealing at each fixed stop seal. (WQD submersible pump manufacturer)
Product Details

Usage conditions:

Can work continuously and normally under the following usage conditions:
1. The working medium is non corrosive clean water, with a sand content of no more than 0.10% by volume and a particle size of no more than 0.20mm.
2. The temperature of the medium exceeds 40 ℃, and the pH value of the medium is between 6.5-8.5.
3. Electric pumps should be used within the range of their rated head.
4. The electric pump should be immersed in water for use, and the diving attempt should not exceed 3m. The electric pump should be at least 0.5m above the bottom of the water, but should not get stuck in the water.
5. The power frequency is 50Hz, the voltage for single-phase is 220V, the voltage for three-phase is 380V, and the voltage fluctuation range is 0.9-1.1 times the rated value

Precautions for use

1. Install leakage protector
Leakage protector, also known as life protector, can be understood from the three words "life protector". Because submersible pumps work underwater, they are prone to electrical leakage, which can cause energy loss and even lead to electric shock accidents. If a leakage protector is installed, as long as the leakage value of the submersible pump exceeds the operating current value of the leakage protector (generally not exceeding 30mA), the leakage protector will cut off the power supply of the submersible pump to avoid energy waste caused by leakage and ensure safety. (WQD submersible pump manufacturer
2. Do not turn on the power supply if the voltage is abnormal
Due to the relatively long low-voltage power supply lines in rural areas, it is common for the terminal voltage of the lines to be too low. When the phase voltage is lower than 198 volts and the line voltage is lower than 342 volts, the speed of the submersible pump motor decreases. When it does not reach 70% of the rated speed, the centrifugal switch will close, causing the starting winding to be energized for a long time and generate heat or even burn out the winding and capacitor. On the contrary, excessive voltage can cause the motor to overheat and burn out the windings. Therefore, during the operation of the submersible pump, the operator must observe the power supply voltage value at all times. If it is below 10% of the rated voltage and above 10% of the rated voltage, the motor should be stopped to identify the cause and eliminate the fault.
3. Avoid frequent switching
Do not frequently turn on and off the submersible pump, as it will generate backflow when the electric pump stops. If it is turned on immediately, it will cause the motor load to start, resulting in excessive starting current and burning out the winding. Due to the high current during startup, frequent startups can also burn out the windings of the submersible pump motor.
4. Do not let the submersible electric pump work under overload for a long time
To avoid long-term overload operation of submersible electric pumps, do not pump water with high sediment content and observe whether the current value is within the specified value on the nameplate at any time. If excessive current is found, stop the machine for inspection. In addition, the dehydration operation time of the electric pump should not be too long to avoid overheating and burning out the motor.
5. The rotation direction of the motor should be correct
The rotation direction of the motor should be clarified. There are many types of submersible pumps that can produce water in both forward and reverse directions, but the water output is small and the current is high in reverse. If the reverse time is long, it will damage the motor winding.WQD submersible pump manufacturer

6. Cable installation and insulation resistance requirements for submersible electric pumps
When installing a submersible pump, the cable should be overhead and the power line should not be too long. When diving or lifting the submersible pump, do not put force on the cable to avoid causing the power line to break. When the submersible pump is working, do not sink into the mud, otherwise it may cause poor heat dissipation of the motor and burn out the motor winding. During installation, the insulation resistance of the motor should not be less than 0.5 megohms.
7. Check and inspect frequently, discover problems and fix them in a timely manner
Regularly check the motor. If cracks are found on the lower cover, damaged or ineffective rubber sealing rings, etc., they should be replaced or repaired in a timely manner to avoid water infiltration into the submersible pump.