ZWIN-WQMS06 Drinking Water Quality Monitoring Station
Product Introduction:
ZWIN-WQMS06 drinking water quality monitoring station is a highly integrated automatic monitoring system. With a multi parameter online monitoring instrument for water quality as the core, it integrates monitoring sensors, automation control, wireless communication transmission, intelligent information technology, and other technologies to conduct real-time online monitoring of the on-site water environment, reflecting the water quality status and changing trends in a real and systematic manner, and providing accurate and timely warnings of water pollution.
Application fields:
Waterworks, water supply pipelines, secondary water supply for residential areas, swimming pools, drinking water, etc.
technical indicators:
PH
Measurement principle: Glass electrode method
Range: 0~14PH
Accuracy: 0.1PH
Resolution: 0.01PH
Repeatability:±0.1PH
Response time:<15 seconds
Low turbidity
Measurement principle:scattering method
Range:0~2/20NTU
Accuracy±2%
Resolution:0.001/0.0001NTU
Repeatability:±5%
residual chlorine
Measurement principle:Three electrode constant voltage method
Range:0~1/5/20mg/L
Accuracy±2%FS
Resolution:0.01/0.001mg/L
Repeatability:±2%FS
Response time:<30s
temperature
Measurement principle:Thermal resistance method
Range:-10~60℃
Accuracy±0.2℃
Resolution:0.1℃
Repeatability:±0.2℃
Response time:<15s
total chlorine
Measurement principle:Three electrode constant voltage method
Range:0~1/5/20mg/L
Accuracy±2%FS
Resolution:0.01/0.001mg/L
Repeatability:±2%FS
Response time:<30s
Technical Specifications:
1. Display interface: high-definition color touch screen;
2. Transmission unit: RS485 Modbus RTU standard protocol, wireless network transmission;
3. Cleaning function: Anti polarization cleaning technology for residual ammonia sensor measurement surface, turbidity sensor with scraper brush design, time controlled automatic cleaning flow structure design, flushing and cleaning of pH sensor measurement surface through inlet flow rate;
3.Protection level: IP68, 1 bar;
4.Dimensions: 320 * 438 * 221 (mm);
5.Installation method: wall mounted, clamp type;
6.Working voltage: AC220V;