The ACR series multifunctional power meter used in low-voltage circuits is a network power meter designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It can measure all conventional power parameters, such as three-phase voltage, current, active power, reactive power, power factor, frequency, active energy, and reactive energy. And this instrument is equipped with 4 photoelectric isolation switch input contacts and 2 relay control output contacts, which can be used in conjunction with intelligent circuit breakers to achieve remote signaling and remote control operation of the circuit breaker. Ankerui Electric Energy Meter PZ96L-E4/C
The AMC series multifunctional power meters used in low-voltage circuits are network power meters designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. They can measure all conventional power parameters, such as three-phase voltage, current, active power, reactive power, power factor, frequency, active energy, and reactive energy. And this instrument is equipped with 4 photoelectric isolation switch input contacts and 2 relay control output contacts, which can be used in conjunction with intelligent circuit breakers to achieve remote signaling and remote control operation of the circuit breaker. This series of network power instruments is mainly used in fields such as substation automation, distribution network automation, residential power monitoring, industrial automation, energy management systems, and intelligent buildings.Ankerui Electric Energy Meter PZ96L-E4/C













In the application of power distribution facilities today, the distribution safety of substations is crucial. It can achieve real-time monitoring of the power supply and distribution circuit of substations, not only displaying the power consumption status of the circuit, but also having network communication function. It can be combined with data collectors, computers, etc. to form a power monitoring system. The system realizes the analysis and processing of collected data, real-time display of the operating status of each distribution circuit in the substation, and can pop up alarm dialog boxes for opening and closing, load exceeding limits, and generate various energy reports, analysis curves, graphics, etc., which facilitate remote meter reading, analysis, and research of energy. The system operates safely, reliably, and stably, providing a real and reliable basis for solving electricity problems.
The Acrel-2000 power monitoring system from Ankerui has the function of storing and managing real-time and historical power parameters. All real-time collected data, sequential event records, etc. can be saved to the database. In the query interface, users can customize the parameters, time, or select the updated record data to be queried, and display them in a report format.
Main function: Query the operating parameters of each circuit or equipment at a fixed time. The electrical parameter information displayed in the report should include: phase current, three-phase voltage, total power factor, total active power, total reactive power, positive active energy, etc. The electrical parameter report also supports exporting Excel format files, and can also export PDF format files according to user requirements.
PZ96L-E4/C Ankerui Electric Energy Meter
Ordinary operation functions are written in JSP and published on the server, which can be accessed by any networked PC. The database adopts Oracle database running on the Windows Server system platform. In addition, the ordinary operation functions and the function of directly controlling the water and electricity meter were rewritten and integrated in VB language, running on an industrial computer. If there is a TCP/IP network interruption, remote operation cannot be performed or the server fails, the same operation can be directly performed on the water and electricity meter through the industrial computer.
Recharge: Multiple recharge methods can be implemented, such as service point recharge, campus card load recharge, mobile SMS recharge, phone appointment recharge, etc., without time and space restrictions, as long as there is permission to recharge;
Query: Multiple query methods can be implemented, such as service point query, campus network website query, mobile phone query, etc., which can query timely information, historical data, recharge records, usage balance and other various information;
Zeroing: System administrators can remotely reset single/batch tables, easily completing the initialization work before student check-in;
Transfer: When students change dormitories, they can use the transfer function without the need to operate the water and electricity meters on site;
Force on/off: This function can be used in special circumstances;
Insufficient balance alarm: A threshold for insufficient balance alarm can be set. When the balance in the table is below this threshold, an automatic alarm will be triggered. It can be notified through various methods such as administrator report notification, mobile SMS notification, email notification, campus network query notification, etc;
Fault detection: Administrators can perform fault detection on all water and electricity meters through the network, accurately locate them, and when a certain meter malfunctions, the system will automatically sound an alarm;
Separate permission management: Manage the system according to different permissions, with different management functions for each permission;
Data import function: Student dormitory information can be imported from the freshman reporting system or EXCEL spreadsheet;
Report function and printing: It can generate relevant reports suitable for financial and dormitory management needs, and students can also print them for verification after recharging;
Threshold setting: Administrators can set thresholds for water and electricity prices, overdraft amounts, loss ratios, etc;
System management: It can manage dormitory conditions, operator permissions, and other aspects of the system;
Security backup and disaster recovery function: It has security backup and disaster recovery functions, and with the dual machine hot backup of the server, it can ensure the security of data;
Data encryption measures: Relevant data is encrypted during storage and transmission to ensure data security;