Welcome Customer !

Membership

Help

Guangdong Aipei Testing Equipment Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Guangdong Aipei Testing Equipment Co., Ltd

  • E-mail

    apkjtsx@foxmail.com

  • Phone

    13316686114

  • Address

    Building B, Qianhong Industrial Park, No. 53 Wanbu Road, Changping Town, Dongguan City

Contact Now

Automotive parts constant temperature and humidity test room

NegotiableUpdate on 02/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The constant temperature and humidity test room for automotive parts is used to test the performance indicators of aerospace products, information electronic instruments, materials, electrical and electronic products, as well as various electronic components in high and low temperature or humid and hot environments. It can simulate and control high and low temperature environments, as well as humid and hot conditions, providing comprehensive environmental adaptability testing for products. This device takes into account multiple factors in its design and manufacturing to ensure that it can accurately simulate complex natural environmental conditions, thereby helping businesses and research institutions evaluate the reliability and durability of their products. ?

Product Details

Automotive parts constant temperature and humidity test roomUsed to test the performance indicators of aerospace products, information electronic instruments, materials, electrical and electronic products, as well as various electronic components in high and low temperature or humid and hot environments. It can simulate and control high and low temperature environments, as well as humid and hot conditions, providing comprehensive environmental adaptability testing for products. This device takes into account multiple factors in its design and manufacturing to ensure that it can accurately simulate complex natural environmental conditions, thereby helping businesses and research institutions evaluate the reliability and durability of their products. ‌

Automotive parts constant temperature and humidity test roomTechnical Specifications:

Studio size: 3000 x 2000 x 3000mm (D depth x W width x H height, volume 18M3), other sizes can also be customized

External dimensions: Based on the customer's site, the actual dimensions shall prevail

Temperature and humidity range: Temperature: 0~+80 ℃; -20~+80℃; -40~+80℃; -70~+80℃,30~98%

Temperature fluctuation: ≤± 0.5 ℃ (tested at constant temperature)

Temperature uniformity: ≤ 2 ℃ (tested at constant temperature)

Temperature deviation: ≤± 1 ℃ (tested at constant temperature)

Heating rate: RT~+80 ℃ for about 30 minutes

Linear heating: 3 ℃/min (can be controlled at 0.1-3 ℃/min according to customer needs)

Cooling rate: Nonlinear cooling rate of 1 ℃/min (can be controlled according to customer needs from 0.75 to 1 ℃/min)

The bottom plate of the box can bear the following loads:

(a) Bottom plate load: 1000kg/m2.

(b) The installation location of the laboratory is sunken to ensure that the laboratory is parallel to the ground, facilitating the entry and exit of the test samples.

(c) The bearing capacity of the bottom plate is ensured by a 100mm horizontal channel steel to ensure that the laboratory is installed on a flat surface. The insulation layer of the bottom plate of the laboratory is equipped with load-bearing wooden blocks. A 5mm anti slip SUS304 anti slip stainless steel plate is added on top of the stainless steel bottom plate to ensure uniform force distribution throughout the entire bottom plate.

Execution and compliance with standards and testing methods

GBT 10586-2006 Technical Conditions for Damp Heat Test Chamber

GB/T2423.2-2008 Environmental testing for electrical and electronic products Part 2: Test methods Test B: High temperature IEC 60068-2-2:2007

GB/T2423.1-2008 Environmental testing for electrical and electronic products Part 2: Test methods Test A: Low temperature IEC60068-2-1:2007

GB/T2423.3-2006 Environmental testing for electrical and electronic products Part 2: Test methods Test Cab: Constant temperature test IEC 60068-2-78:2001

Precautions

(Please be sure to pay attention to the following matters, otherwise we will not be responsible for the consequences)

1. Before use, check if the voltage is correct. Please use the voltage indicated on the machine to avoid excessive electricity and potential fire hazards.

2. Check if the direction of motor operation is normal. If there is gas discharge from the air outlet, it is considered normal. (Only applicable to models with three-phase voltage of 380V).

When there is a significant difference between the displayed temperature and the actual temperature (measured by a standard thermometer), the components and internal parameters of the circuit board cannot be adjusted arbitrarily. The company should be notified to send staff to handle it.

4. Do not open the machine door casually when the temperature changes during use.

5. Do not place the machine in damp places or rinse it directly with water to prevent electrical leakage.

6. It is prohibited to place flammable and volatile substances such as alcohol and adhesives inside the machine to prevent accidents.

7. When using flammable materials near the machine, they should be kept away appropriately to prevent accidents.

8. Please be careful when placing items into the machine. If the temperature is above 60 degrees, please wear high-temperature gloves.

When the timer (temperature up timer) is working, the AL light on the temperature control meter lights up, indicating that the temperature has reached the set range and the machine starts to maintain temperature.

When holding the temperature, if there is an overshoot or underestimation between the displayed temperature and the set temperature, automatic calculation is required.

11. The heater inside the machine should be regularly inspected to remove dust and other impurities.