Phone
18752030246
-
Address
Room 201, Building 8, 777 Longwu Road, Xuhui District, Shanghai
Shanghai Shujun Instrument Equipment Co., Ltd
18752030246
Room 201, Building 8, 777 Longwu Road, Xuhui District, Shanghai
Sample ultrasound pause timer: can be set within the range of 1-99 seconds.
0.5ml adapter: equipped with a knob type 0.1ml centrifuge tube sample explosion-proof and leak proof safety fixing lock, while using at least 12 0.5ml tubes, the reaction volume of a single sample can be between 5 μ l and 50 μ l
1.5ml adapter: equipped with a knob type 1.5ml centrifuge tube sample explosion-proof and leak proof safety fixing lock, while using 6 1.5ml tubes. The reaction volume of a single sample can range from 100 μ l to 300 μ l
15ml adapter: including aluminum sample height adjustment ring, using 6 15ml centrifuge tubes at the same time, the reaction volume of a single sample can be between 500 μ l and 2ml
1. The instrument includes: integrated ultrasonic power/time adjustment host ultrasonic water tank and anti noise cover, adapter rotating cover, 0.65ml adapter, and electromagnetic valve cooling circulation machine
2. Control mode:
-Ultrasonic sample volume: With different adapters, the volume of ultrasonic samples can reach 2ml or more or 5ul or less
-Applicable sample types: Applicable sample types include 0.1ml, 0.65ml, 1.5ml, and 15ml centrifuge tubes, which do not require the use of special materials (such as glass) consumables, saving experimental costs
-The sample needs to be crushed in a closed container without producing infectious flying mist, and no additional ultrasonic probe needs to be inserted
-Allowable single operation quantity: 12 samples can be processed at once (requires 0.1 or 0.65ml adapter)
-The sample needs to be able to automatically rotate at a constant speed during ultrasound to ensure consistent crushing effect
3. Equipped with instrument lifespan monitoring device
4. Instrument overheat protection device
5. Sample crushing method: Ultrasonic crushing is required
6. Nucleic acid sample fragmentation size: 1kb~100bp or smaller
7. The instrument includes a set of 0.65ml adapters: with a knob type 0.65ml centrifuge tube sample explosion-proof and leak proof safety fixing lock, at least 12 0.65ml tubes need to be used simultaneously. The reaction volume of a single sample can range from 10 µ l to 100 µ l
8. Ultrasonic power/time adjustment accessories:
-Ultrasonic on/off dual timer: It can automatically control the number of ultrasonic on/off cycles (number of cycles), and the timing range can be set from 1 to 99 cycles
9. Multi functional timer: Sample ultrasound start timer: can be set within the range of 1-99 seconds.
Sample ultrasound pause timer: can be set within the range of 1-99 seconds.
10. Equipped with automatic shutdown protection device for instrument overheating, monitoring device for instrument usage status, and self state detection device for startup operation
11. Equipped with a cooling circulation system and solenoid valve, it can be linked with the ultrasonic host. When the ultrasonic is started, the cooling system pauses the circulation. When the ultrasonic is paused, the cooling system starts without interfering with the ultrasonic efficiency
12. Equipped with a pause function, the anti noise upper cover is lifted, and the ultrasonic instrument pauses immediately. After closing the cover, ultrasound continues, and the sample ultrasound time can be controlled, which increases the safety of experimental personnel operating the instrument,