1. The dedicated MCU chip and high-quality components for electric meters have a measurement accuracy higher than B (1.0) level.
2. Large screen LCD display, real-time display of key data such as total electricity consumption, used electricity, remaining electricity, etc.
3. The optoelectronic isolation RS-485 communication interface effectively prevents destructive interference such as lightning strikes and surges, greatly reducing maintenance difficulty.
4. Automatic power outage for overdue payments, automatic incoming calls for recharging, and reminders for minimum balance.
5. Remote manual power on/off, timed automatic power on/off, overload tripping, time limited current, malignant tripping, temperature detection, infrared control, air conditioning recognition and other functions.
6. Record time functions such as zeroing, timing, remote tripping, and remote closing.
7. Built in hardware clock circuit, with local data storage, supports remote precise timing and multi rate setting.
8. Measure, record, and measure the voltage, current, power, and power factor of the current module meter; Record events such as zeroing, timing, remote tripping, and remote closing.
9. Autonomous embedded software ensures normal operation when disconnected from the internet, realizing metering deduction and policy control, strict password verification and security authentication, and secure and reliable data transmission.
10. The dual circuit rail smart meter can independently measure and strategically control the two circuits of dormitory air conditioning and lighting sockets.
Specifications |
Parameters |
||
|
measure
|
voltage |
working voltage |
220V 50Hz (80%~120%Ub) |
power consumption |
<5VA (single-phase) |
||
impedance |
>2MΩ |
||
accuracy class |
Error ± 0.2% |
||
electric current |
Input Current |
10 (40) A (startup<0.4% Ib) |
|
output current |
Maximum output current per channel 60A |
||
power consumption |
<1VA (single channel rated current) |
||
accuracy class |
Error ± 0.2% |
||
power |
Active, reactive, and apparent power, with an error of ± 0.5% (based on phenotype requirements) |
||
metering |
electric energy |
Active energy level B (1.0) |
|
pulse |
pulse width |
80±20ms |
|
Pulse constant |
1600imp/kWh |
||
communication |
Interface and Communication Protocol |
DL/T645-2007 Custom Modbus RTU (corresponding to different series) |
|
Baud rate |
Supports 1200bps~9600bps |
||
environment |
operation temperature |
-25℃~+55℃ |
|
storage temperature |
-40℃~+70℃ |
||
relative humidity |
≤ 95% (no condensation) |
||
Data storage |
Data retention time after power outage: greater than or equal to 10 years |
||
Continuous work |
Mean Time Between Failures (MTBF): greater than 80000 hours |
||
Specification and size