The APM521 network power meter is designed according to IEC international standards and has functions such as full energy measurement, energy statistics, energy quality analysis event recording, and network communication. It is mainly used for comprehensive monitoring of power supply quality in the power grid. This series of instruments is equipped with feature rich DI/DO modules and AO modules, which can flexibly achieve full power measurement and switch status monitoring of electrical circuits. Export UL certified electric meters
Product Details

introduction:

The APM521 network power meter is designed and built in strict accordance with IEC international standards, with rich functions such as accurate measurement of full power, comprehensive statistics of electrical energy, in-depth analysis of electrical energy quality, event recording, and network communication. It is mainly used for comprehensive monitoring of power supply quality in the power grid. This series of instruments is equipped with fully functional DI/DO modules and AO modules, which can flexibly and efficiently achieve full power measurement of electrical circuits and real-time monitoring of switch status.

Against the backdrop of accelerated energy management and surging smart grid construction, smart meters with international certification have become an emerging growth engine in the field of power equipment exports. For enterprises, selecting products that have passed * * certification is not a simple market choice, but a "ticket" to enter * * markets such as North America and the European Union. It is also a strategic key to shaping brand reputation and ensuring long-term stable cooperation. Among them, UL certification, as a widely accepted safety standard in the North American market, works hand in hand with the CE certification of the European Union to jointly build the core compliance barrier for products to move towards internationalization.

出口带UL认证电表

1、 Application scenarios of electric meters

Commercial buildings, such as office buildings, shopping malls, hotels, etc., are used to accurately measure electricity consumption for cost accounting and energy management.

Industrial facilities: factories, workshops, and other places that monitor the electricity usage during the production process, helping optimize equipment operation and energy efficiency.

Data center: Accurately measure and monitor the power consumption of servers, network equipment, etc., to ensure the stability and reliability of power supply.

In the field of new energy, such as solar power plants, wind farms, etc., they are used to measure the generated electricity and the interaction with the power grid.

Public facilities: including hospitals, schools, sports centers, etc., to ensure reasonable allocation and management of electricity usage.

Charging station: used for electric vehicle charging stations to accurately measure the energy consumption during the charging process.

Smart Grid: As a part of the smart grid system, it enables remote meter reading, power monitoring, and control functions.

Residential communities: Measure and manage the electricity usage of residential buildings to facilitate the collection of electricity bills and energy consumption analysis.

3、 Function Introduction

measurement parameters

Measured

parameters

Full power measurement

Total electrical measurement

Four quadrant electrical energyFour quadrant reactive energy, phase separated energy, apparent energyMultiple rate electricity

Four-quadrant energyTheFour - quadrant reactive electric energyTheSplit phase electricityTheApparent energyTheMulti-rate energy

pulse output

Pulse output

Total active and reactive power pulse output

Total active power, total reactive power electrical energy pulse output

demand

Demand

Three phase currentmeritoriousPowerno meritPowerapparentReal time power demand and maximum demand(Include timestamp)Last month's maximum demand(Include timestamp)

Three-phase current, active power, reactive power, apparent power real-time demand and maximum demand (including timestamp), last month's maximum demand (including timestamp).

Extreme value statistics

Extreme

value statistics

Currentline voltagephaseVoltagemeritoriousPowerno meritExtreme values of power and other electrical parameters for this month and last month(Include timestamp)

Current, line voltage, phase voltage, active power, reactive power and other electrical parameters extreme values of this month and last month (including time stamps)

power quality

Power quality

Current, line voltagephaseVoltage imbalance

Unbalance of current, line voltage, phase voltage

Voltage phase angle, current phase angle

Voltage phase angle, current phase angle

Voltage and current total(Odd, even)harmonic content

Total (odd, even) harmonic content of voltage and current

Voltage and current subharmonics(2-63time)content

Harmonic content of voltage and current (2-63 times)

Voltage peak coefficient

Voltage peak coefficient

Telephone waveform factor

Telephone waveform factor

currentKcoefficient

Current K-factor

vector graphic

Vector

Real time waveform of voltage and current

Voltage and current waveform

Fundamental voltage, fundamental current, fundamental power factor

Fundamental voltage ,current and power factor

Voltage deviation, frequency deviation

Voltage deviation, frequency deviation

Positive, negative, and zero sequence voltages

Positive - sequence voltage, negative - sequence voltage, zero - sequence voltage

Positive, negative, and zero sequence currents

Positive - sequence current, negative - sequence current, zero - sequence current

Freeze electrical energy

Frozen electric energy

24Freeze electrical energy31Daily frozen electricity12Monthly freezing of electrical energy, timed freezing of electrical energy

24 - hour frozen electric energy, 31 - day frozen electric energy, December frozen electric energy, regular - time frozen electric energy

Event log

Event logging

DIDORecord, can record the most recent128articleDIDOrecord

DIDO records, which can record the last 128 DID records

police record

Alarm logging

Can record recent events128Alarm records

The last 128 alarm records can be recorded

communication

Communication

Modbus - RTUagreementDL/T 645-2007specification

Modbus - RTU protocol, DL/T 645-2007 statute

Optional features

Optional features

4Road switch input,2Road switch output

4-channel digital input and 2-channel digital output

2Analog output,4-20mA

2 channels of analog output, 4-20mA

Expand the second pathRS485communication,Modbus - RTUagreement

Expand the second RS485 communication channel with Modbus - RTU protocol

Expand Ethernet communication,MODBUS-TCPagreementFTPagreement

Expand Ethernet communication with the MODBUS-TCP protocolFTP protocol


4、 Electrical technical parameters

project
Item

performance parameters
Performance Parameters


voltage
Voltage

rated voltage

ULTheCE
Rated voltageULTheCE

66V AC L-N 115V AC L-L

230V AC L-N 400V AC L-L

277V AC L-N 480V AC L-L

400V AC L-N 690V AC L-L

rated voltageCPA
Rated voltage

CPA

three-phase three-wire

3P3L

three-phase four-wire

3P4L


3x100V

3x380V

3x690V

3x57.7/100V

3x220/380V

3x400/690V

overload
Overload

1.2 Multiple rated value (continuous)
1.2 times rating (continuous)

2 Continuous double rated value1 second

2 times the rating for 1 second

power consumption
Power consumption

<1VA

accuracy class
Accuracy class

error±0.2%
Error ±0.2%

current
Current

ratedcurrent

ULTheCE
Rated currentULTheCE

1AThe5A

ratedcurrent

CPA
Rated current

CPA

0.015-0.0756A(Active electrical energy)Active energy

3X1(6)A(Reactive energy)Reactive energy

overload
Overload

1.2 Multiple rated value (continuous)
1.2 timesrating (continuous)

10 Continuous double rated value 1 second
10times the rating for 1 second

power consumption
Power consumption

<0.2VA

accuracy class
Accuracy class

error±0.2%
Error ±0.2%

power
Power

Active, reactive, apparent power, error±0.2%
Active, reactive, apparent power, error ±0.2%

grid frequency
Grid frequency

ULTheCE

50Hz/60HzError±0.2%
50Hz/60Hz, error ±0.2%


CPA

50HzError±0.2%

50Hzerror ±0.2%

response rate
Response rate

200ms(Voltage, current, power)
200ms (voltage, current, power)


≤1s(Electricity)
≤1s (electrical energy)

Measurement category

Measurement category

66ULN(20%) 115ULL(20%) CAT

230ULN(20%) 400ULL(20%) CAT

277ULN(20%)480ULL(20%) CAT

400ULN(20%) 690ULL(20%) CAT

measurement
Metering

electric energy
Electric energy

active energyDlevel

Active energyClass D

Reactive energy (accuracy level)2level
Reactive energy (Class 2 accuracy)

auxiliary power supplyAuxiliary power supply

AC/DC 85-300V

Electromagnetic Compatibility
electromagnetic compatibility

Electrostatic discharge immunityIV level
Electrostatic discharge immunity class IV

Electrical fast transient burst immunityIVlevel
Electrical fast transient burst immunity class IV

surge(impact)immunityIVlevel
Surge (shock) immunity Class IV

safety
Security

power frequency withstand voltage
Power frequency withstand voltage

Between communication and signal inputAC4kV 1min
Between communication and signal input,AC4kV 1min

insulation resistance
Insulation resistance

Input and output terminals to the casing>100MΩ
Input and output terminals to casing >100MΩ

communication
Communication

Interface and Communication Protocol
Interface and communication protocol

RS485口、Modbus RTUspecification
RS485 interface and Modbus RTU protocol

Communication address range
Communication address range

Modbus RTU:1~ 247

Baud rate
Baud rate

support1200bps-38400bps
Support 1200bps-38400bps

environment
Environment

Operating Temperature
Operating temperature

-40℃+70℃

Storage temperature
Storage temperature

-40℃+80℃

relative humidity
Relative humidity

≤95%(No condensation)
≤95%(without condensation)

altitude
Altitude

2000m

2000m5000m(For power supply only)AC/DC85-265V, voltage277/480VBelow)

2000m5000mOnly applicable to the power supply with the voltage range of AC/DC 85-265V and the voltage below 277/480V.

Installation environment

Installation environment

Indooruse

pollution level

Pollution degree

Class2


5、 Installation and wiring

5.1 Overall dimensions

出口带UL认证电表

5.2 Wiring guidance

出口带UL认证电表

6、 Conclusion

Export UL certified electric metersWith its outstanding safety performance, complete functional system, and diverse application scenarios, it stands out in the field of power monitoring, demonstrating significant advantages and broad development potential. It not only provides accurate and stable data support for power management in different industries, but also utilizes Ethernet communication technology to move the power system towards a new stage of intelligent development. With the rapid development of technology and the continuous increase in energy management demand, UL certified Ethernet communication meters are expected to make great strides in a wider range of fields, effectively promoting the power industry to steadily move towards safer, more efficient, and smarter directions. For the vast number of users, it is important to have a deep understanding and make scientific choicesExport UL certified electric metersWe will effectively improve the level of power management and help achieve the goals of energy conservation, emission reduction, and sustainable development.