Product description:
ADT300W-O2Fixed oxygen concentration detectorIt is a gas detector newly created by Outit Technology on the basis of the original, using * sensors and a new 32-bit low-power processor; The dashboard display interface displays both numerical values and progress bars, presenting a beautiful and elegant appearance; The circuit adopts 4-layer wiring, which has stronger resistance to weak signals and interference; Independent high-precision imported 16 bit AD chip and * signal processing algorithm, with higher and more stable measurement data accuracy; 4~20mA, RS485, 200~1000HZ multiple output signals can be selected, making it easy to connect to various alarm controllers, PLCs, DCS and other control systems; Explosion proof structural design can be applied in various hazardous industrial sites; The product is widely used in various fields such as petroleum, chemical, metallurgical, power, municipal, fire protection, industrial production, university scientific research experiments, and exhaust environmental monitoring.
Product Features:
◆ * High performance sensors with high measurement accuracy, good repeatability, and long service life;
Adopting an independent 16 bit AD chip and a 4-layer circuit board design, it has stronger resistance to weak signals and interference;
◆ mg/m3、 Multiple units such as ppm, VOL, and LEL can be selected when leaving the factory;
◆ Equipped with an embedded 32-bit ultra-low power processor and signal processing algorithm, it has fast response speed and stability;
◆ Automatic protection function against high concentration gas impact, with factory reset settings to prevent misoperation;
The instrument is equipped with an infrared remote control, which can be operated through the remote control without opening the cover, making it simple and convenient;
◆ Three wire system with 4-20mA, RS485, 200~1000HZ signal output options, relay output, data recovery, data storage and other functions;
Two cable entry ports for easy on-site installation;
◆ Independent chamber structure, easy sensor replacement, no need for on-site calibration;
The mechanical design of the air chamber adopts high-quality high-strength aluminum profiles, which are wear-resistant, corrosion-resistant, and suitable for complex and harsh industrial environments. The reasonable and scientific air chamber design ensures the accuracy of real-time monitoring by sensors;
The explosion-proof level is Exd II CT6, certified by the National Explosion proof Electrical Inspection Center.
Technical parameters of ADT300W-O2 fixed oxygen concentration detector:
name |
description |
Gas detection: |
Oxygen O2 |
Detection Principle: |
Principles of electrochemistry |
Detection method: |
Fixed online long-term continuous detection, diffusion based detection method; |
Fixed online continuous detection, using an external air pump to achieve pump suction flow detection (optional air pump); | |
Installation method: |
Wall mounted, pipelineIntegrated (Pipe type external thread specification: M45X1.5mm, optional pipe adapter screw joint, weldable) |
Measurement range: |
01000ppm、5%VolThe25%Vol、30%Vol、100%Vol(The measurement range is optional at the factory, and if the range is not listed, it can be customized) |
resolving power: |
1ppm,0.01%VOL |
Accuracy: |
≤± 1% FS (actual concentration, higher accuracy requirements depending on sensor performance) |
Operation method: |
Infrared remote control for remote and close range operation, convenient setup |
Repeatability: |
≤±1% |
Zero drift: |
≤± 1% (F.S/year) |
Response time: |
≤ 20 seconds (T90) |
Recovery time: |
≤ 20 seconds |
Explosion proof mark: |
Exd II CT6 |
Protection level: |
IP66 |
|
Output signal: |
Users can choose according to their actual on-site environmental needs, with a maximum transmission distance of 2000 meters (single core 1mm2 shielded cable) |
Three wire 4-20mA current signal output, can be connected to various control systems such as alarm controllers, PLCs, DCS, etc. (standard configuration) | |
Digital signal RS-485 output,ModBus RTU communication protocol(Optional features) | |
Frequency signal 200~1000Hz output (optional function) | |
Two sets of relay outputs: passive electric shock capacity 220VAC 0.5A or 5VDC 0.5A | |
Remote transmission and status alarm of detection data can be achieved through wireless module function (optional function); Can achieve Ethernet access | |
Main material |
Shell: ADC12 aluminum alloy, sturdy, wear-resistant and corrosion-resistant (batch can choose 316 stainless steel shell) |
Gas chamber: Made of high-strength, wear-resistant, and corrosion-resistant aluminum profiles, sturdy and durable (316 stainless steel gas chambers can be optionally selected for batches) | |
Operating Temperature |
-30 ℃~+60 ℃ (customized for special requirements) |
Working humidity: |
≤95%RH, No condensation (humidity>90% RH, condensation can be equipped with a filter) |
relative humidity |
10%~95%RH |
Power supply: |
24VDC (normal operating voltage range 12-30VDC) |
Power consumption: |
1.5W |
working pressure: |
≤200Kpa |
Size: |
180mm * 140mm * 92mm (height * width * thickness) |
Weight: |
About 1.6Kg |
Execution standard: |
GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Standard configuration: |
Host, remote control, packaging box, manual, warranty card/certificate of conformity |
*: |
The whole machine comes with a one-year warranty and free maintenance during the warranty period. |