GLQ315 Touch based Data Management Machine

NegotiableUpdate on 04/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Overview: GLQ315 Touch Data Management Machine is the core device of our company's intelligent electricity management system developed for the management characteristics of university apartments. It integrates data collection, data uploading, data querying, and control operations. The downstream has 2-4 RS485 communication interfaces, and the upstream has TCP/IP network interfaces. It is compatible with 4G and WIFI wireless upload communication interfaces. The product uses UNIX operating system and is compatible with Android system, which can achieve cross platform operation. It is equipped with embedded software of Credit Suisse Data Gateway to achieve functions such as timed data collection, storage, and breakpoint continuation. It has advanced technology, simple operation, and stable operation.
Product Details

1. Hardware configuration: The data management machine is composed of ARM11 CPU, 2G memory (with external storage card, support for solid-state 128GB hard drive, optional screen size), LINUX operating system (compatible with mainstream operating systems such as Windows and Android), wireless transmission, various interfaces, buzzer, indicator lights, and other components.

2. Load performance: Each serial port should have no less than 32 terminal devices (capable of collecting various measuring instruments such as water meters, electricity and power meters, gas meters, heat meters, ultrasonic flow meters, electromagnetic flow meters, and environmental parameter sensors such as PM2.5), with a maximum collection rate of 192002400-19200.

3. Data collection: Upload data to servers through wired or wireless networks, support direct connection to cloud servers, upload collected data in real time and on schedule, support communication protocols in GB/T 19582-2008 (ModBus), DL/T 645-2007, CJ/T 188-2004, and State Grid Q/GDW 1376.1-20131376.1 protocol. Each interface is independently configurable and supports extended function applications and development.

4. Data Management: Install the Credit Suisse Data Gateway embedded platform software to achieve local and remote data queries, terminal control, and system management, making it convenient for non central management personnel to control terminal devices and query central data on site.

5. Data freezing: The collected data can be temporarily frozen and stored (time can be set) to maintain the continuity of the data after disconnection.

6. Discontinue transmission: Automatically save the collected data in case of network failure, and upload it in sequence when the network is restored.

7. Status monitoring: Supports sending heartbeat packets to the server at regular intervals. The heartbeat packet time and content can be set (the heartbeat packet time is the same as keepalive). If the device does not receive server data within the heartbeat interval, it will automatically send heartbeat content to the server.

8. Command parsing: It can parse commands sent by the server to read data from the collection device and provide feedback on the execution results to the server.

9. Device networking: Provide at least two Ethernet interfaces (LAN function, assigning IP addresses to devices). Through these Ethernet interfaces, user Ethernet devices can easily access the public network, forming a network centered around this product. All devices in the network work in the same network segment as this device, and can communicate with each other. They can be accessed normally through mobile terminals, servers, and other devices.

10. Intelligent anti disconnection: supports online detection, online maintenance, automatic redialing when disconnected, ensuring that the device is always online.

11. Electromagnetic compatibility: meets the testing requirements of GB/T 17626.2-2006, including electrostatic discharge, electromagnetic radiation, transient pulse, surge impact, and other anti-interference and safety standards.


Project Parameters
basic configuration The data management machine adopts ARM11 CPU, 2G memory (with external storage card), supports solid-state 64GB hard drive, and is expandable
operating system LINUX operating system, supports WinXP and Win7, supports cross platform development
UPLINK

Network ports: 1-2 100M/10M adaptive Ethernet ports, supporting AUTO MDI/MDIX dual level lightning protection

4G: Equipped with a standard SIM card slot and a 4G antenna SMA interface

WIFI: Equipped with WIFI ORI GPS antenna SMA interface and external GPS antenna

Downstream Interface

RS485: 2-6 fully isolated RS485 interfaces (supporting transmit and receive indicator lights), with three-level protection

RS323: 2-4 fully isolated RS232 interfaces, three-level protection

Supports the highest level of 4KV protection for 10/700uS testing in GB/T 17626.5-2008 standard

◆ ±15kV Human Body Model

◆ ±15kV IEC1000-4-2 Air Discharge

power interface

Input voltage: DC 9~36V;

Power protection: GB/T 17626.5-2008 standard level 4 (4KV) 8/20uS lightning strike test

Overall Power Consumption Maximum power consumption ≤ 3W
Other interfaces

TF card interface: onboard 1 self loading TF card slot supporting TF card expansion storage

USB HOST interface: onboard 1 USB HOST interface supports expanding USB peripherals

Console UART interface: The external interface of the Console UART port is a Type-C socket, which integrates a USB to serial port chip internally, making it convenient for users to directly use the serial port for debugging and maintenance

Other configurations

RTC clock: internally integrated real-time clock, onboard 1 CR2032 battery

Buzzer: One onboard buzzer can be used for alerting or programming to produce a prompt sound

Indicator lights: 1 power indicator light, 1 system programmable indicator light, COM1~COM6 transceiver indicator light

FUN button: The programmable button is used by default to update the file system and restore the factory default IP address

Whole machine weight 360g
Specification and size Select screen sizes such as 9 inches, 12 inches, 14 inches, etc. according to requirements
Working temperature/humidity -40-85 ℃/20% -90% no condensation


Product specifications and sizes: Depending on the size of the display screen, there are different specifications and sizes available