working principle
If there is a very high frequency (usually taken asWhen a current of 1MHz flows from the oscillator into the sensor coil, the sensor coil generates a high-frequency oscillating magnetic field. If a piece of metal approaches this magnetic field, eddy currents will be generated on the surface of the metal. The intensity of eddy current varies with the distance between the sensor coil and the metal, as this distance affects the impedance of the sensor coil. Therefore, distance measurement can be achieved by measuring impedance. The eddy current sensor outputs a DC voltage signal that is a single valued function of distance. As shown in the figure below:
Application field
CZ600Eddy current displacement sensorIt can be widely used in online monitoring and fault diagnosis of axial displacement, radial vibration, differential expansion, eccentricity, phase detector, swing, and shaft speed of large rotating machinery. Large machinery such as steam turbine units, water turbine units, compressors, large cooling pumps, induced draft fans, gearboxes, coal mills, blowers, water pumps, wind turbines, etc
It has also been widely used in material identification, surface roughness measurement, metal plate thickness measurement, material deformation measurement and other application fields.
feature
1. High sensitivity
2. High resolution
3. Wide measurement range
4. Dynamic response width
5. Can be transmitted over long lines
6. Strong adaptability, able to work in environments with oil, water, high air pressure, and strong interference
7. Non contact measurement and monitoring of displacement, vibration, speed, size, thickness, without mechanical measurement force
Technical Specifications
Probe specifications |
Φ5mm |
Φ8mm |
Φ11mm |
Φ25mm |
|
probe diameter |
5 mm |
8 mm |
11 mm |
25 mm |
|
measurement range |
1 mm |
2 mm |
4 mm |
12 mm |
|
linear error |
<1% |
<1% |
<1% |
<1.5% |
|
Static sensitivity |
Depending on the output signal and corresponding range |
||||
power supply voltage |
1、 +24Vdc (output signals: 1-5V, 1-10V, 4-20mA) 2. -24Vdc (output signal: -2~-18V) Note: Different output methods result in different power supplies |
||||
output signal |
1~5V、1~10V 、4~20mA、-2~-18V |
||||
output method |
Three wire system (power supply, signal, common terminal) |
||||
resolution |
0.001mm |
||||
System temperature drift |
0.1%/℃ |
||||
frequency response |
0~5KHz(0.5dB) |
||||
Output ripple |
Voltage output:<20mV; Current output:<30uA |
||||
operating power consumption |
<10mA (excluding 4-20mA current output) |
||||
output load |
Voltage output: Load capacity<10K Current output: Load capacity<500 Ω |
||||
Environmental temperature during calibration |
(20±5)℃ |
||||
|
use temperature |
Proximitor |
-30℃~+70℃ |
|||
probe |
-40℃~+150℃ |
||||
cable |
-40℃~+150℃ |
||||
weight |
500g±3% |
||||
Total length of cable |
5m or 9m |
||||
Extend cable length |
4m、4.5m、8m、8.5m |
||||
Probe cable length |
1m、0.5m |
||||
Normal working environment |
No strong magnetic field, no corrosive vapor liquid, no strong vibration source |
||||
insulation resistance |
>500MΩ |
||||
Insulation strength |
>500V |
||||
Size of preamplifier |
90mm(W)×35mm(L)×70mm(H); Installation of guide rails or screws |
||||
Installation of preamplifier |
1. Bottom plate installation, 51mm × 51mm, using four M4 × 12 GB29-76 bolts for installation; 2. Rail installation, can be easily installed on standard 35mm rails. |
||||
Connection of preamplifier and probe cable |
Using SpringLoc terminals with automatic fastening function, wiring can be done without the need for installation tools. As there is no need for bolt fixation, it will not loosen. |
||||