SA-5500 portable vibration meter

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product Details

1. Selection of measuring points for vibration meters: Use a vibration meter to test the bearings and axial endpoints of the main equipment, and provide on-site inspection records. Each measuring point must correspond to each other.

2. Measurement cycle: It is necessary to measure once every two weeks when the equipment has just undergone or is close to major repairs; Test once a month during normal operation; If there is a significant change between the measured value and the previous measurement value, the testing density should be strengthened to prevent sudden accidents from causing malfunctions and shutdowns.

3. Measurement value judgment basis: Refer to international standard ISO2372.

Speed:600~1200r/min, Vibration measurement range: 10-1000Hz. Usually, during normal operation of the equipment, the detection speed value is within the range of 4.5-11.2mm/s (for units above 75kW) for monitoring purposes. If it exceeds 7.1mm/s, major repairs should be considered. The determination of this value not only considers the capacity of the equipment motor, but also takes into account factors such as strong work continuity, safety and reliability. In short, the use of a vibration meter in conjunction with other detection instruments is beneficial for analyzing the operating status of the equipment. When used in conjunction with instruments such as vibration meters, oil quality analyzers, motor fault detectors, and alignment instruments, it can more accurately determine the operation of the equipment.

Technical Indicators:
1. Measurement range: Vibration displacement (P-P): 0-1999 μ m
Vibration velocity(RMS):0~199.9mm/s
vibration acceleration( O-P) :0~199.9m/s2
2. Amplitude measurement error:
[1] Frequency response range and amplitude error:
Vibration displacement(P-P): 10~500Hz,≤±5%
Vibration velocity(RMS): 10~500Hz,≤±5%
Vibration acceleration(O-P):10~1000Hz,≤±10%
[2] Amplitude linear error:
Vibration displacement(P-P):0~20μm,≤±10% >20μm,≤±5%
Vibration velocity(RMS): 0~2.0mm/s, ≤±10% >2.0mm/s,≤±5%
Vibration acceleration(O-P):0~2.0m/s2, ≤±10%>2.0m/s2,≤±5%
3. Low voltage indication: If the battery voltage is below 5.5V, a low voltage prompt will be displayed. At this time, the battery should be replaced.
4. Data retention time: When the measurement button is released, the measured data can be retained for one minute.
5. Indication fluctuation: The indication fluctuation is not greater than one resolution.
6. Usage environment: Environment temperature: 0-40 ℃ Relative humidity: ≤ 80%
Atmospheric pressure:75~106Kpa
7. Size: 185 (H) × 68 (W) × 30 (D) mm
8. Weight: 230g (including battery)