E-mail
2952632948@qq.com
-
Phone
18921988865
-
Address
No. 308, Yuanqu Road, Zhouzhuang Town, Kunshan City, Suzhou City, Jiangsu Province
Shangyi Vibration Instrument (Suzhou) Co., Ltd
2952632948@qq.com
18921988865
No. 308, Yuanqu Road, Zhouzhuang Town, Kunshan City, Suzhou City, Jiangsu Province
lImplement intelligent processing: alarmThe values of I and II can be set arbitrarily through the panel buttons
lThe panel buttons can adjust the range value without the need for potentiometer adjustment, making it convenient for on-site debugging
lIf you don't press the operation key for one minute, you can return to the running state by yourself
lAlarm delay adjustment range1~60Seconds to prevent false alarms caused by on-site interference
lFrequency range:10~1000Hz
lquantity Cheng:050.0mm/s
laccurate indeed Degree:±1%(Full scale)
lCurrent output:4~20mA
lSwitching output:DC 30V/5AorAC250V/5A(Normally open)
lAlarm setting: Any setting within the full range
lEnvironmental temperature: During operation:0~65℃
During storage:-30~80℃
lRelative humidity: to95%Not condensing
lPower supply voltage220VAC/50Hz±10% 50mA
lOverall dimensions:160×80×230mm
lHole size:152+1×75+1mm
通道Display box:In operation, display channelsVibration value; In the parameter setting state, display the parameter flag;
通道II Display Box:In operation, display channelsII vibration value; In the parameter setting state, display the parameter value corresponding to the parameter flag;
Alarm indicator light:When the measured value exceeds the alarm setting range, the alarm indicator light will turn on;
SETKey:Long press the key5Enter the parameter setting state in seconds; In the parameter setting state, press this key to enter the parameter editing state. After editing the parameters, press this key to confirm the modified parameters. After setting the parameters, long press again5In seconds, return to the working state and save the set parameters;
+Key:In the parameter viewing state, press this key to view the next parameter; In parameter editing mode, you can add to the parameters to be edited1The range of numbers is0~9;
-Key:In the parameter setting state, press this key to view the previous parameter; In parameter editing mode, the parameters to be edited can be subtracted1The range of numbers is0~9;
(◄)Left cursor shift key:In parameter editing mode, move the number of parameter digits to be set, such as from single digits to hundreds digits;
This instrument has been debugged before leaving the factory, and users can use it directly. If you need to view the factory parameters of the instrument or make modifications, you can perform the following operations.