Welcome Customer !

Membership

Help

Spectral Quality Analysis and Testing Technology (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

smart-city-site>Products

Spectral Quality Analysis and Testing Technology (Shanghai) Co., Ltd

  • E-mail

  • Phone

    18321902003

  • Address

    12F, Dongjin International Building, No. 501 Jinyuan 4th Road, Jiading District, Shanghai

Contact Now

Thermo ISQ single quadrupole gas chromatography-mass spectrometry

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Thermo ISQ single quadrupole gas chromatography-mass spectrometry • Full Source RemovalTM improves the normal operation time of the instrument, providing guarantee for daily operation. Stable scanning speed can be used throughout the entire mass range and combined with gas chromatography to improve sample analysis flux. The expanded mass range provides more diversified analysis capabilities. The full scan/SIM alternating scan technology can confirm and screen compounds in the same analysis
Product Details
Product Introduction

Thermo ISQ single quadrupole gas chromatography-mass spectrometry

ISQ characteristicscharacteristic

•Full Source RemovalTM(Disassemble the ion source as a whole) Improve the normal operation time of the instrument and provide guarantee for daily operation.
Stable resources can be utilized throughout the entire range of quality numbersscanning speedAnd combined with gas chromatography to improve sample analysis flux.
The expanded range of quality metrics provides more diverse analytical capabilities.

The full scan/SIM alternating scan technique can confirm and screen compounds in the same analysis.

• Quality range of 1.2-1100 u
The vacuum locking device supports the overall disassembly of the ion source without the need for vacuum
S-type pre quadrupole helps reduce noise
ExtractaBrite ion source improves analytical flexibility and durability
• Fast acquisition rate compatible with gas chromatography
The detachable cylindrical ion source design makes maintenance convenient and allows for easy switching of ionization modes
Full scan/SIM alternate scan enables qualitative and quantitative analysis in one injection
The fine tuning control design of dual filaments ensures stable operation
QuanLab Forms analysis application software helps you collect, view, and report GC-MS data
Analyze flexibility
Electron bombardment ionization (EI) mode is suitable for unknown substance analysis - GC-MS standard configuration
Chemical ionization (CI), including positive ion chemical ionization (PCI) for molecular weight confirmation and negative ion chemical ionization (NCI) for improving selectivity and sensitivity. The standard configuration of its pulsed positive and negative ion chemical ionization (PPINICI) allows for alternating scanning of PCI and NCI in a single injection.
Extended functions
• Liquid and headspace sampler options
DEP/DIP direct injection rod
Various injection port options with large volume injection capability
EnviroLab Forms and ToxLab Forms designed according to specific market needs, supporting data collection, review, and reporting based on different workflows
Various gas chromatographs meet your laboratory analysis needs

• Compatible with other injection techniques such as thermal desorption, sweep capture, and solid-phase microextraction (SPME)