The ADT800W-TVOC-PID waste gas VOC concentration detector circuit adopts a 4-layer wiring, which has stronger resistance to weak signals and interference; Independent high-precision imported 16 bit AD chip and * signal processing algorithm, with higher and more stable measurement data accuracy;
Product Details

ADT800W-TVOC-PIDVOC concentration detector for exhaust gasProduct Features:

High performance PID photoionization principle sensor with high measurement accuracy, good repeatability, and long service life;
Adopting an independent 16 bit AD chip and a 4-layer circuit board design, it has stronger resistance to weak signals and interference;
The dashboard display interface design features beautiful and elegant readings, reflecting humanized detail design;
◆ White, orange, and red backlight design, indicating normal and alarm status at a glance;
Multiple units including mg/m3, ppm, VOL, and LEL can be selected at the factory;
ADT800W-TVOC-PID waste gas VOC detector adopts an embedded 32-bit ultra-low power processor, equipped with * signal processing algorithm, with fast response speed and stability;
◆ Automatic protection function against high concentration gas impact, with factory reset settings to prevent misoperation;
The instrument is equipped with an infrared remote control, which can be operated through the remote control without opening the cover, making it simple and convenient;
◆ Three wire system with 4-20mA, RS485, 200~1000HZ signal output options, relay output, data recovery, data storage and other functions;
Two cable entry ports for easy on-site installation;
◆ Independent chamber structure, easy sensor replacement, no need for on-site calibration;
The mechanical design of the air chamber adopts high-quality high-strength aluminum profiles, which are wear-resistant, corrosion-resistant, and suitable for complex and harsh industrial environments. The reasonable and scientific air chamber design ensures the accuracy of real-time monitoring by sensors;
The explosion-proof level is Exd II CT6, certified by the National Explosion proof Electrical Inspection Center.

ADT800W-TVOC-PIDVOC concentration detector for exhaust gasTechnical Specifications:

name

description

Gas detection:

Organic volatile gases TVOC/VOC

Detection Principle:

PID photoionization principle

Detection method:

Fixed online long-term continuous detection, diffusion based detection method;

Fixed online continuous detection, using an external air pump to achieve pump suction flow detection (optional air pump);

Installation method:

Wall mounted, pipe integrated (pipe type external thread specification: M45X1.5mm, optional pipe adapter screw joint, weldable)

Measurement range:

0-2ppm, 20ppm, 50ppm, 200ppm, 2000ppm, 6000ppm, 10000ppm (factory optional, range not listed can be customized)

resolving power:

0.01ppm (0-100ppm), 1ppm (above 1000ppm)

Accuracy:

≤± 1% FS (actual concentration, higher accuracy requirements depending on sensor performance)

Operation method:

Infrared remote control for remote and close range operation, convenient setup

Repeatability:

≤±1%

Zero drift:

≤± 1% (F.S/year)

Response time:

≤ 15 seconds (T90)

Recovery time:

≤ 20 seconds

Explosion proof mark:

Exd II CT6

Protection level:

IP66




Output signal:

Users can choose according to their actual on-site environmental needs, with a maximum transmission distance of 2000 meters (single core 1mm2 shielded cable)

Three wire 4-20mA current signal output, can be connected to various control systems such as alarm controllers, PLCs, DCS, etc. (standard configuration)

Digital signal RS-485 output, ModBus RTU communication protocol (optional function)

Frequency signal 200~1000Hz output (optional function)

Two sets of relay outputs: passive electric shock capacity 220VAC 0.5A or 5VDC 0.5A

Remote transmission and status alarm of detection data can be achieved through wireless module function (optional function); Can achieve Ethernet access

Main material

Shell: ADC12 aluminum alloy, sturdy, wear-resistant and corrosion-resistant (batch can choose 316 stainless steel shell)

Gas chamber: Made of high-strength, wear-resistant, and corrosion-resistant aluminum profiles, sturdy and durable (316 stainless steel gas chambers can be optionally selected for batches)

Operating Temperature

-30 ℃~+60 ℃ (customized for special requirements)

Working humidity:

≤95%RH, No condensation (humidity>90% RH, condensation can be equipped with a filter)

relative humidity

10%~95%RH

Power supply:

24VDC (normal operating voltage range 12-30VDC)

Power consumption:

1.5W

working pressure:

≤200Kpa

Size:

180mm * 140mm * 92mm (height * width * thickness)

Weight:

About 1.6Kg

Execution standard:

GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

Standard configuration:

Host, remote control, packaging box, manual, warranty card/certificate of conformity

*: