FISCHER PHASCOPE PMP10 thickness gauge from Germany

NegotiableUpdate on 02/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PMP10 adopts phase sensitive measurement technology, which is suitable for measuring the thickness of coating on rough substrates or the thickness of nickel plating on steel. For the automotive industry, it is necessary to measure the thickness of paint coatings on aluminum or galvanized steel plates. PMP10 is particularly suitable for electroplating or circuit board industries and can be used to inspect conductive coatings on various substrates. The phase sensitive eddy current method has great advantages in measuring small objects such as screws, nuts, and bolts, because the geometric shape of the measured part has little effect on the measurement itself: even rough surfaces can be measured using PHASCOPE ® PMP10。

Product Details

product description


FISCHER PHASCOPE PMP10 thickness gauge from Germany--------Handheld instrument used to measure the coating thickness of PC boards and electroplated surfaces,PMP10 adopts phase sensitive measurement technology, which is suitable for measuring the thickness of coating on rough substrates or the thickness of nickel plating on steel.For the automotive industry, it is necessary to measure the thickness of paint coatings on aluminum or galvanized steel plates. PMP10 is particularly suitable for electroplating or circuit board industries and can be used to inspect conductive coatings on various substrates.The phase sensitive eddy current method has great advantages in measuring small objects such as screws, nuts, and bolts, because the geometric shape of the measured part has little effect on the measurement itself: even rough surfaces can be measured using PHASCOPE ® PMP10。 This method can also be used for non-contact measurement; For example, the thickness of copper plating on a circuit board can be measured without considering the protective paint coating.






① FISCHER softwareData center

FISCHER DataCenter software is a powerful tool that can be used for PHASCOPE ® PMP10 provides fast and easy data transmission, as well as rich quality control graphic display and statistical analysis functions: statistical process control chart, cumulative frequency chart, and Fischer's own FDD ® (Factory diagnostic diagram). The built-in report editor allows measurement data to be easily processed, archived, and printed as separate inspection reports



PHASCOPE ® PMP10characteristic:

Accurate measurement of nickel, zinc, or copper coating thickness on steel using phase sensitive measurement technology

It can even be measured on rough surfaces

Use DUPLEX to simultaneously measure the paint layer and galvanized layer on galvanized steel plates
Easy post-processing of measurement values using Fischer DataCenter software
Stable handheld measuring device for direct on-site testing

PHASCOPE ® PMP10answerUse:

Nickel coating on steel, copper coating on iron or bronze
Non ferromagnetic metal coatings on non-conductive substrates, such as copper coatings on circuit boards
Hot spray aluminum (TSA) coating on steel
Specially suitable for measuring positions of curved surfaces, convex and concave shapes, as well as rough surfaces
Equipped with special probes for interlayer connection holes in circuit boards
Micro scale coatings on non-magnetic metals, iron, or steel
Micro scale multi-layer system composed of single-layer coating layer






④ To achieve these applications, the following measurement probes are required:

---------Cooperate with the measuring probeESD20ZnMeasure zinc,The thickness of copper, aluminum, and other coatings on steel or iron. Especially suitable for measuring on rough surfaces. The use of phase sensitive eddy current method allows for non-contact measurement,For example, for the measurement of leads.
---------Cooperate with the measuring probeESD2.4Measure the zinc coating on smaller steel components. Due to its smaller measurement area and the advantages brought by the phase sensitive eddy current method, no special calibration is required for components of different geometric sizes.

---------Cooperate with the measuring probeESD20NiMeasure the electroplated nickel layer on steel or iron components. Two different measurement frequencies (60 kHz or 240 kHz) can be selected based on the thickness range of the nickel layer.

---------Cooperate with the measuring probeESD20CuMeasure the thickness of copper-clad laminates on printed circuit boards, even under solder resist. The measurement frequency operates at 60 kHz or 240 kHz, allowing for the selection of the optimal frequency based on the current application.

---------Cooperate with the measuring probeESL080Measure the thickness of the copper wall inside the through-hole on the printed circuit board.ESL080 is a needle shaped measuring probe that needs to be inserted into a through-hole for measurement (as shown in the image on the left). An external metal sheath protects the measuring coil from corrosion and mechanical damage.This measuring probe is designed to induce eddy currents that flow along the longitudinal axis of the copper sleeve. In this way, the diameter of the copper plate layer has no effect on the measurement, and the size of the annular ring has only a small impact.