-
Phone
15921165535
-
Address
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
Duzhi Instrument (Shanghai) Co., Ltd
15921165535
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
German Elektrophysik (EPK) MiniTest 7400 thickness gauge-----Combining innovative user interface concepts with highly convenient data managementMiniTest 7400High end coating thickness gauge with multiple optional and replaceable external sensors.Graphic display can directly display statistical values, trend charts, histograms, and simplified user guidance.MiniTest The 7400 coating thickness gauge can measure non-magnetic coatings (paint, synthetic materials, chromium, etc.) on ferromagnetic substrates (steel) and insulating coatings (varnish, enamel, synthetic materials, etc.) on conductive substratesCopper, stainless steel).MiniTest 7400 has a wide measurement range and can measure thin coatings (such as galvanized coatings) in the sub micron range, which is difficult
Geometric targets (such as measuring steel needles,From grooves and holes to thick coatings (such as flame retardant coatings in steel structures, rubber coatings, etc.).
※User guides in 4 languages, others in development
※Coating thickness measurement with an accuracy of up to 100 millimeters/4 inches

MiniTest 7400
Main features:Sensor Integrated Digital Signal Processing (SIDSP) ®) Improved accuracy and repeatability※
Multi functional probe with automatic substrate detection function, capable ofRapid measurement of steel and non-ferrous metals
※Wear resistant probes have almost no service life
※temperature compensation
※High precision characteristic curves in factory calibration, with up to 50 data points
※Store up to 100000 values
※
Infrared Data Transfer (IrDA) to PC and PrinterProbe design selection:Different types of cable sockets are more flexible to meet testing requirements.Each standard probe can provide a straight cable socket or a right angle design, which can measure difficult to access similar pipes and hollow parts. Due to the harsh environment caused by paint or dust pollution, special probes are required.In order to provide protection in harsh environments, a specially designed and sturdy probe series is provided(HD probe). These probes have special grouting seals to protect the probe equipment. The external spring device makes the probe easy to clean.For rough surfaces,
|
“F2 HD”Type probes are particularly suitable for rough surfaces.
apply toNon destructive coating thickness measurement:Non magnetic coatings such as varnish, enamel, chromium, and zinc on ferromagnetic substrates (such as steel),
|
|
|
Insulation coatings such as varnish, anodized aluminum, and non-ferrous metals (such as aluminum)) |
|
|
MiniTest 7400 |
500 |
|
technical data |
Number of data memory groupsStorage data volumemake an appointment |
|
25,000 |
A readingStatistical values (per batch group)Number of readings, * large value, * small value,Mean, standard deviation, coefficient of variation, group statistics(Standard settings/Free configuration ),Process Capability IndexCPand |
|
CPK |
Histogram, Trend Chart5Calibration Mode |
|
*Many more |
Point calibration, user adjustable compensation value |
|
Limit value monitoring |
Acoustic and optical alarm prompts when exceeding the limit valueMeasurement unitμm,mm,cm,mils,inch |
|
, |
thou |
|
Storage temperature |
–10°C … 60°C; 14°F … 140°F |
|
operate temperature |
4–20°C … 70°C; -4°F … 158°Fdata interfacejointAA (LR06type)Battery, or optional external power supply(90 – 240 V |
|
~ |
/ 48 – 62 Hz)The calibration procedure complies with international standards and specifications |
|
ISO,SSPC, |
Swedish standards, Australian standardspower supplyIrDA ® 1.0Infrared interface, optionalUSBand |
|
RS232 |
Adaptersize153 mm x 89 mm x 32 mm |
|
; |
6 inch x 3.5 inch x 1.3 inchweight310 g; 11 oz.( |
|
The host includes a battery |
)display160 x 160pixel |
|
LCD |
With backlightstandard2064DIN EN ISO 14612178,2360,2808,3882,19840,,,AS3894;SS 184160, SSPC-PA 2,IMO-PSPC,ASTM B 244,B 499,D 7091 |
|
,E376 |
||
|
MiniTest 7400 |
Probe technical parameters |
Probe model |
|
measuring range |
application area |
F0.5 |
|
0-0.5mm |
Non magnetic coatings, small workpieces, and thin coatings on steel |
F1.50-1.5mm |
|
Non magnetic coating on steel |
Small workpieces |
F1.5-90 |
|
0-1.5mm |
Non magnetic coatings, thin coatings on steel, particularly suitable for measuring pipes or difficult to access objects |
F2.0 HD |
|
0-2.0mm |
Non magnetic coating on steel, sturdy design suitable for harsh environments, suitable for rough coating testing |
F5 |
|
0-5mm |
Non magnetic coating on steel |
F15 |
|
0-15mm |
Measurement of wall thickness of thick paint, porcelain or plastic coatings on tanks and pipelines, as well as protective coatings such as glass, plastic, rubber, concrete lining, etc. (using steel plates as the substrate) |
F35 |
|
0-35mm |
Measurement of wall thickness of thick paint, porcelain or plastic coatings on tanks and pipelines, as well as protective coatings such as glass, plastic, rubber, concrete lining, etc. (using steel plates as the substrate) |
N0.2 |
|
0-0.2mm |
Insulation coatings, small workpieces, and thin coatings for non-ferrous metals |
N0.7 |
|
0-0.7mm |
Insulation coatings, small workpieces, and thin coatings for non-ferrous metals |
N0.7-90 |
|
0-0.7mm |
Thin insulation coatings for non-ferrous metals, particularly suitable for measuring pipes or difficult to access objects |
N2.5 |
|
0-2.5mm |
Insulation coating and standard probe for non-ferrous metals |
N7 |
0-7mmThick coating and wall thickness measurement of insulation coatings for non-ferrous metals (using steel plates as substrates)Standard configurationPlace:MSoft 7Professional software, German/english/French/4Spanish operating instructionsQuick check cardsectionAABattery,LR06
TypePlastic suitcaseprobe:Optional SIDSP ® The probe includes a certificate