Konster Intelligent Fully Automatic Pressure Calibration Instrument $r $n ● Main Features $r $n $r $nConST811A Pneumatic Edition $r $n $r $n ■ Built in automatic pressure source, up to 10MPa; $r $n $r $n ■ Dual operation mode of touch and keyboard;
Kongster Intelligent Fully Automatic Pressure Calibration Instrument
● Main features
ConST811A Pneumatic Edition
■ Built in automatic pressure source, capable of reaching up to 10MPa;
Dual operation mode of touch and keyboard;
The accuracy level can reach up to 0.01;
■ Can be independently charged externally.
ConST811A Hydraulic Edition
■ Built in automatic pressure source, capable of reaching 100MPa;
Dual operation mode of touch and keyboard;
The accuracy level can reach up to 0.01;
■ Can be independently charged externally.
Kongster Intelligent Fully Automatic Pressure Calibration Instrument
General indicators
| project |
Description/Indicator |
| display |
7-inch TFT touch screen |
|
| interaction |
Simultaneously supporting color screen touch and keyboard operation |
| power supply |
Battery or adapter |
|
| battery |
Typical working hours: 12 hours; Charging method: Charge with the host or independently; Charging time: less than 5 hours |
| Pressure connection |
By connecting the console and hose, it can be expanded to M20X1.5 The specifications for quick connect internal threads vary depending on the version. |
| Electrical measurement connection |
Φ 4mm banana socket |
| communication method |
US B、LAN、WiFi、 Bluetooth (BLE) (The wireless communication module can be removed as required) |
| Load capacity |
Typical 50mL hydraulic version, maximum 80mL |
| Task Management |
More than 1000 tasks and data storage |
| pressure unit |
25 commonly used units, 5 user-defined units |
| environmental conditions |
Operating temperature: (0~50) ℃; Storage temperature: (-20~70) ℃; Environmental humidity:<90% RH, non condensing; Altitude:<3000m |
| certification |
CE |
| size |
Hydraulic version: (300X220x192) mm Other: (300X193X192) mm |
| weight |
Barometric and meteorological versions: 7.8kg; Micro differential pressure version, differential pressure version: 6.8kg Hydraulic version: 11.9kg |
Electrical measurement indicators
| project |
scope |
resolution |
indicator |
|
| measurement |
MV measurement |
(-300~300)mV |
1μV |
±(0.008%RD+6μV) |
|
V measurement (Automatic range) |
(-5~5)V |
0.02mV |
±(0.008%RD +0.1mV) |
|
| (-12~12)V |
0.1mV |
±(0.008%RD+0.24mV) |
|
| (-30~30)V |
0.1mV |
±(0.008%RD+0.6mV) |
|
MA measurement (Automatic range) |
(-25~25)mA |
0.1μA |
±(0.008%RD +1.0μA) |
|
| (-50~50)mA |
0.1μA |
±(0.008%RD+2.0μA) |
|
| Switch measurement |
Mechanical switches NPN type switch PNP type switch |
N/A |
Response time<10ms If the switch is energized, Voltage range (3~30) V |
|
| output |
current output |
(0~2.5)mA |
0.05μA |
±(0.008%RD +0.2μA) |
|
| (2.5~25)mA |
0.5μA |
±(0.008%RD+1.0μA) |
|
| voltage output |
(0~16)V |
0.25mV |
±(0.008%RD+0.5mV) |
|
| DC power supply |
(16~30)V |
1V |
1V step, maximum load capacity of 70mA, Ripple peak to peak value ≤ 40mV |
|
| bus communication |