The microbial glucosidase ELISA kit $r $n uses a double antibody sandwich enzyme-linked immunosorbent assay. Add the specimen, standard sample, and HEP labeled detection antibody to the pre packaged captured antibody package in one go, incubate and wash. $r $n uses substrate nmE for color development, while TEB is converted to blue under the catalysis of chemical enzymes and to yellow under the action of acid. The depth of color is positively correlated with the reagents in the sample. Use an enzyme-linked immunosorbent assay (ELISA) reader to measure the absorbance at a wavelength of 450nm and calculate the sample concentration.
Product Details

Microbial Glucosidase ELISA Kit

Brand: Baili Lai

Specification: 96t/48t

微生物葡萄糖苷酶(Glucosidase)ELISA试剂盒

Microbial Glucosidase ELISA Kit

Operation skills:

1. Remember to gently wipe and dry the enzyme labeled plate surface with absorbent paper after adding the enzyme reagent.

2. Reasonably arrange the amount of testing to avoid too many reaction plates causing long waiting times for plate washing.

3. When sucking liquid, use a gun with a range close to the required amount to reduce errors.

4. It is necessary to conduct a double well experiment to ensure the accuracy of the data and reflect the precision of the reagent kit.

5. The sample diluent should be added using a dispenser and its accuracy should be regularly checked.

To prevent sample evaporation, place the reaction plate in a sealed box covered with a damp cloth during the experiment, and cover or film the enzyme-linked immunosorbent assay plate.

7. Unused enzyme-linked immunosorbent assay (ELISA) plates or reagents should be stored at 2-8 ℃. Please prepare and use horseradish peroxidase working solution according to the required amount. Do not reuse diluted horseradish peroxidase working solution.

In the ELISA kit experiment, after adding the sample, it should be placed in the incubator in a timely manner. If there are many samples, they should be operated in batches. Strictly control the operation time according to the instructions to prevent artificially prolonged incubation time, which may cause non-specific binding to adhere tightly to the reaction well and make it difficult to clean thoroughly.

9. The remaining samples and waste should be sterilized with high-pressure steam at 121 ℃ for 30 minutes, or treated with disinfectants such as 5.0g/L sodium hypochlorite for 30 minutes before being discarded.

When washing the ELISA kit, each well should be filled with liquid to prevent any free enzymes from washing the well.

11. Leave one hole as a blank zeroing hole for each experiment. No reagents are added to this hole, only the substrate solution and 2N H2SO4 are added at the end. When measuring, first use this hole to adjust the OD value to zero.

12. When manually washing boards, add detergent each time. It should be left to stand for 15-30 seconds, and the washing solution from one enzyme labeled well should not be splashed into another enzyme labeled well to prevent cross contamination. After shaking off the detergent, place the enzyme-linked immunosorbent assay (ELISA) plate on a towel or absorbent paper and pat dry.

When there are doubts about the results of the sample, other testing methods need to be used for verification.

14. Prepare the solution with deionized water or double distilled water, do not use tap water.

15. When using a micro sampler, the nozzle should be replaced after extracting liquids from different bottles, even if standard solutions are being extracted.

16. When suctioning liquid, the speed should not be too fast to avoid the generation of bubbles, and the amount of ELISA kit suctioned may not be accurate enough.

17. When suctioning liquids, it is necessary to use a micro sampler with a range close to the required amount to reduce errors.
Disclaimers

1. The reagent kit is for research purposes only and should not be used for clinical or human experiments. Any consequences arising from this shall be borne by the experimenter, and our company shall not be held responsible.

2. Strictly follow the instructions for operation. If the experimenter violates the instructions, the consequences shall be borne by the experimenter.

Related products:

BLL105676EPlant ammonium transporter (ANT) ELISA kit

BLL105677EPlant tomato yellow leaf curl virus (TYLCV) ELISA kit

BLL105678EPlant yellow mosaic virus (YMV) ELISA kit

BLL105679EPlant Flower Fruit Virus (PaMV) ELISA Kit

BLL105680EPlant Monogalactose Glycyrylglycerol (MGDG) ELISA Kit

BLL105681EPlant Catechin ELISA Kit

BLL105682EPlant Lignin Synthase (LNS) ELISA Kit

BLL105683EPlant Pectin ELISA Kit

BLL105685EPlant pheophylline dehydrogenase (PPH) ELISA kit

BLL105686EPlant Cell Wall Acid Converting Enzyme (CWI) ELISA Kit

BLL105687EPlant Blueberry Shock Virus (BlShV) ELISA Kit

BLL105688EPlant Tobacco Thread Virus (TSV) ELISA Kit

BLL105689EPlant blueberry blast virus (BBScV) ELISA kit

BLL105690EPlant Blueberry Carrier Virus (BSSV) ELISA Kit