EGR protection function
✔ Grounding fault protection for distribution lines
✔ General load grounding fault protection
✔ Single phase grounding fault protection
✔ High voltage grounding fault protection
EGR product characteristics
| Product Information |
| product scope | EOCR |
| Model Name | EGR digital grounding current fault protection relay |
| Protection type | Ground fault protection (zero sequence detection method) |
| [Us] Rated input voltage | 100...240 V AC/DC |
| power frequency | 50...60 Hz |
| Protection and regulation range | 0.03...20 A |
| Installation method | 35mm rail installation or screw fixation |
| Electrical/mechanical characteristics |
| Contact configuration | 1 C/O GR) |
reset method |
Manual reset Electrical reset: 0... 1 second Automatic reset: 0.3 seconds |
| Time Setting |
Ground fault action time 0.2... 2 seconds |
| [Ue] Rated working voltage | 690 V AC 50... 60 Hz main circuit complies with IEC 60947-4-1 |
| [Uimp] rated pulse withstand voltage |
6 kV complies with IEC 60947-4-1 |
| Relay power consumption | 3 W |
| display mode | 2 LED displays |
| [Ith] Continuous current | 5 A control circuit |
| Allow current |
250 V, 5 A AC |
| wiring |
Control circuit cable: 2 x 1... 1.5 mm ², flexible cable with terminals - M3 Control circuit cable: 2 x 1... 1.5 mm ², flexible cable without terminals - M3 Control circuit cable: 1 x 1... 2.5 mm ², flexible cable with terminals - M3 Control circuit cable: 1 x 1... 2.5 mm ², flexible cable without terminals - M3 |
| tightening torque |
Control circuit: 0.8... 1.2 N · m, suitable for cables, diameter 4.7 mm Main circuit: 2.5 N · m, suitable for terminal clamps, diameter 11 mm |
| Dimensions and Weight |
height |
52 mm |
width |
70 mm |
depth |
71 mm |
Product weight |
0.245 kg |
| Usage environment |
| Operating temperature | -20... 60 ° C (compliant with IEC 60947-4-1) |
Storage temperature |
-40…85°C |
| Working altitude | 2000 meters |
| IP rating | IP20, Compliant with IEC 60529 |
| Fire resistance | 650 ° C, compliant with IEC 60695-2-12 |
| impact resistance | 15 gn 11 ms (符合 IEC 60068-2-7) |
| Vibration resistance |
Panel installation 4 gn in accordance with IEC 60068-2-6 35mm rail installation 2 gn in accordance with IEC 60068-2-6 |
| Surge immunity | 6 kV complies with IEC 61000-4-5 |
| insulation withstand voltage |
The connection between the 2 kV 50... 60 Hz enclosure and the circuit complies with IEC 60255-5 1 kV 50... 60 Hz mutual contacts comply with IEC 60255-5 The internal circuits between 2 kV 50... 60 Hz comply with IEC 60255-5 |
| Electromagnetic Compatibility |
Radio frequency electromagnetic field immunity of 10 V/m, level 3, in compliance with IEC 61000-4-3 Electrostatic discharge immunity 8 kV air, 6 kV contact discharge, in accordance with IEC 61000-4-2 Fast transient immunity of 2 kV, compliant with IEC 61000-4-4 RF conducted immunity of 10 V, compliant with EN 61000-4-6 RF conducted immunity level, compliant with EN 55011 |