PFZ-WRDUH Schneider EOCR Communication Protector
EOCR-PFZ protection function
✔Overcurrent (timed limit: 0.2... 30 seconds, inverse time limit: 1... 30 class)
✔ Low current (OFF, 0.2... 30 seconds)
✔ Phase loss (OFF, within 3 seconds)
✔ Reverse (0.1... 0.3 seconds)
✔ Current imbalance (8 seconds)
✔ Stall (0.5 seconds after D-Time)
✔ Blocked rotation (0.1... 10 seconds)
✔ Grounding (0.05, 0.1... 10 seconds)
✔ 短路(0...20秒)
★ Two channel 4... 20mA analog output, current transmitter function
★ Modbu RS-485 communication function
Product Features of EOCR-PMZ
| Product Information |
| product scope | EOCR |
| Model Name | EOCR-PFZ motor protection relay |
| Protection type |
Overload protection, In>overcurrent setting Underload protection, In<undercurrent setting During operation, there is stalling, with In>1.5... 5 times the overcurrent setting phase loss protection Ground fault, Ig>Ground current setting Reverse phase protection Lock up during startup, In>2... 10 times overcurrent setting Unbalance protection, 5... 50% |
| Analog output range | 4...20 mA |
| Communication Port Protocol | Modbus RTU |
| [Us] Rated input voltage | 85...250 V AC/DC |
power frequency |
50...60 Hz |
| Protection and regulation range |
0.5...100 A 0.03...10 A, Turn off timed grounding fault powerflow 0.03... 1 A inverse time limit - ground fault current |
| Installation method |
35mm DIN rail panel mounting |
| Electrical/mechanical characteristics |
| Contact type and configuration | 1 NC+1 NO, OL ; 1 NO, GR ; 1 NO, SH |
| reset method |
Manual reset Automatic reset: 0.3... 1200 seconds Electrical reset: 0... 1 second |
| Time Setting |
Overcurrent action time: 0.2... 30 seconds (timed limit) Delay time at startup: 1... 200 seconds, off Undercurrent action time: 0.5... 30 seconds Ground fault action delay time during startup: 1... 10 seconds, off Overcurrent action time: 1... 30 levels (inverse time limit) Ground fault action time: 0.05, 0.1... 10 seconds (timed limit) Ground fault action time: 0.05... 10 levels (inverse time limit) |
| [Ue] Rated working voltage |
690 V AC 50... 60 Hz main circuit complies with CSA 690 V AC 50... 60 Hz main circuit complies with IEC 60947-4-1 600 V AC 50... 60 Hz main circuit complies with U |
| [Uimp] rated pulse withstand voltage |
6 kV complies with IEC 60947-4-1 |
| Relay power consumption | 3 W |
| display mode | stripDiagram and7-segment LED display |
| [Ith] Continuous current | 3A control circuit |
| Allow current |
250 V, 3A |
| wiring |
Control circuit cable: 2 x 1... 1.5 mm ², flexible cable with terminals - M3 Control circuit cable: 2 x 1... 1.5 mm ², flexible cable without terminals - M3 Control circuit cable: 1 x 1... 2.5 mm ², flexible cable with terminals - M3 Control circuit cable: 1 x 1... 2.5 mm ², flexible cable without terminals - M3 |
| tightening torque |
Control circuit: 0.8... 1.2 N · m, suitable for cables, diameter 4.7 mm Main circuit: 2.5 N · m, suitable for terminal clamps, diameter 11 mm |
PFZ-WRDUH Schneider EOCR Communication Protector
Overview of EOCR-PFZ
✔Higher measurement accuracy (1% level)
✔Built in dedicated MCU microcontroller unit
✔Protection functions: overcurrent, low current, phase loss, locked rotor, reverse, current imbalance, grounding, short circuit, and dual 4-20mA analog output
✔Modbus RS-485 communication function, supporting a maximum of 200 nodes
✔The protection current range of the main body is 0.5~100A, and the external CT can reach 6000A
✔Built in zero sequence current transformer ZCT, no external configuration required within 100A
✔Digital low-pass filtering function can prevent grounding protection misoperation
✔RTC clock can record fault time,
✔The current time characteristic has definite and inverse time limits that can be selected
✔digital display
♦ The three-phase main circuit current, short-circuit current, and grounding current are displayed in a 5-second cycle and can be displayed with a fixed phase
♦ Fault cause and current value display for easy troubleshooting
✔Three fault records, no data loss due to power outage
✔The running time setting can provide regular maintenance, such as replacing bearings, etc
✔Analog (4~20mA) signal output for centralized management of equipment
✔Ground fault (57-58) output contact status can be customized
✔Zero sequence current detection method can be used to measure the value of grounding leakage current and its operating characteristics can be selected
✔Reset direction: manual (RESET), power-off, and automatic reset
✔Power down modes N and R can be selected ★ Suitable for 20~400Hz frequency conversion environment
✔The terminals are detachable, and the terminal type and penetration type can be freely assembled


EOCRPFZ-WRDZ7W current analog output motor protectorTechnical parameters and product characteristics

EOCRPFZ-WRDZ7W Model Table

Typical Wiring Diagram and Terminal Blocks for EOCRPFZ-WRDZ7W:

EOCRPFZ-WRDZ7W Order Code: