Overview of EOCRI3M420 Schneider Communication Intelligent Protector

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Overview of EOCRI3M420 Schneider Communication Intelligent Protector $r $nEOCR-I3M420 Motor Integrated Protector, Schneider Korea original, guarantees that the product has overcurrent, phase loss, locked rotor, reverse rotation, current imbalance, stall and 4-20mA analog output functions, three-phase current cycle display and fault cause and current value memory query. The main module is installed on a 35mm guide rail, and the display is installed on the cabinet door for real-time current value viewing.
Product Details


Overview of EOCRI3M420 Schneider Communication Intelligent Protector

i3M420

Add 4-20 mA analog output on the basis of i3DM function to achieve seamless data acquisition for field instruments, PLC or DCS; Simultaneously retaining Modbus RTU communication and dual interface parallel output, providing higher flexibility and redundancy for process automation

EOCR-i3M420 概述

32-bit MCU+True RMS measurement, accuracy ± 1%

Protection functions: overload (OC), underload (UC), phase loss (PL), reverse phase (RP), imbalance (Ub), startup stall (Sc), running stall (JA), (optional) short circuit (SH)

Action time characteristics: timed limit, inverse time limit, thermal accumulation inverse time limit

THD total harmonic distortion monitoring: real-time monitoring of three-phase, adjustable alarm threshold

4~20mA analog output(Load)≤ 500 Ω, compatible with ModbusSimultaneously used)

Modbus RTU/RS-485 2400-38 400 bps remote communication

Display: Bar load graph+5-digit seven segment digital tube LED

Three phase current automatic rotation display/manual locking of a certain phase display (manual locking function)

Operation/Fault Records:

• Reasons for tripping and current records of the last 3 faults

Accumulated running time and timeout alarm records

• Limit the number of startup records

Fail Safe mode: independent start stop function (safe mode)

Password protection function: Three digit password to prevent accidental operation; Long term shutdown can restore factory settings

Reset mode: manual, automatic, power-off, remote communication

Structural selection: Terminal T, Bottom hole H, Window W

Three phase/single-phase modeMenu switchable

Compliance and certification: UL, CCC, compliant with EU RoHS


Overview of EOCRI3M420 Schneider Communication Intelligent Protector

EOCR-i3M420Specification Sheet

Basic Information

Manufacturer/Brand

Schneider Electric

Product Range (Series)

EOCRseries

Model Name

EOCR-i3M420Digital motor protection relay (built-in display, integrated)

place of origin

Yishan Factory, South Korea

Authorized General Agent in China

Shanghai Hanshi Electric Automation Equipment Co., Ltd

Protection function setting range

Protection setting range

0.5~32 A(inverse time limit/heat accumulation inverse time limit), use external CT for 32A and above
0.5-80 A (timed limit), external CT is used for 80A and above

The external CT current range can be extended to 800 A

Time Setting

Overload protection OC: timed limit (0.2-30 seconds); Inverse time limit (1-30 classes)

Underload protection UC: timed limit (0.5-30 seconds)

Phase loss protection PL: 0.5 to 5 seconds (can be set to turn off)

Reverse protection RP: Action time 0.15 seconds

Unbalance protection Ub: action time 1-10 seconds, set range 10-50%

Starting blockage Sc:+0.5 seconds after the start delay (D-Time) ends

Running stall JA: 0.2 to 10 seconds

Start delay D-Time

0–200 s, closable

Measurement and communication functions

Analog output

4 – 20 mA (Load ≤ 500 Ω)

communication interface

Communication protocol: Modbus RTU

Communication method: RS-485

Baud rate: 2400~38400 bps

measurement accuracy

± 1%, True RMS (32-bit MCU)

THDmonitor

Display when total harmonic distortion occurs, alarm threshold can be set

Electrical parameter monitoring

Real time display of three-phase current, alarm and action reasons

Electrical and mechanical characteristics

Control power supply (Us)

U:100–240 V AC/DC

B:24 V AC/DC

power frequency

50/60 Hz

Installation method

35 mm DINGuide rail+panel screws

output contact

1NC + 1 NO (95-96/97-98)Overload trip (OL)

Fuse specifications

By 4 A gG

Rated voltage of main circuit [Ue]

600 V AC, 50-60 Hz (main circuit, UL compliant)

690 V AC, 50-60 Hz (main circuit, compliant with CSA)

690 V AC, 50-60 Hz (main circuit, compliant with IEC 60947-4-1)

Impact withstand voltage (Uimp)

6 kV(Complies with IEC 60947-4-1)

reset method

Manual reset (RESET)

Automatic reset (0.5-1200 seconds)

Electrical reset (power-off reset, 0-1 second)

Communication remote reset (via Modbus communication)

display interface

Bar load chart+5-digit seven segment LED

Relay power consumption

3 W

Ith /contact rating

Ith 3 A;250 V AC 3 A

Wiring specifications

Control circuit cable: 2 × 1-1.5 mm ² (with/without terminal flexible cable M3)

Control circuit cable: 1 × 1-2.5 mm ² (with/without terminal flexible cable M3)

Main circuit terminal: 1 × 2.5-25 mm ² (flexible cable M6 without terminal)

tightening torque

Control circuit terminal: 0.8-1.2 N · m (cable diameter 4.7 mm)

Main circuit terminal: 2.5 N · m (terminal clamp diameter 11 mm)

External dimensions/weight

WWindow type (W × H × D): 70 × 74.5 × 83.8 mm0.315 kg

HBottom hole type (W × H × D): 70 × 56.3 × 108.1 mm0.355 kg

TTerminal type (W × H × D): 70 × 91.3 × 108.1 mm0.473 kg

environmental parameters

Protection level

IP20(Complies with IEC 60529)

Operating Temperature

-20~60 ℃ (compliant with IEC 60947-4-1)

Storage temperature

-40~85℃

Using altitude

2000 m

flame retardancy

650℃ (compliant with IEC 60695-2-12)

impact resistance

15 gn, 11 ms (compliant with IEC 60068-2-7)

Vibration resistance

Panel installation: 4 gn (IEC 60068-2-6)

Rail installation: 2 gn (IEC 60068-2-6)

insulation withstand voltage

Between external and circuit: 2 kV (IEC 60255-5)

Between mutual contacts: 1 kV (IEC 60255-5)

Internal circuit: 2 kV (IEC 60255-5)

surge resistance

6 kV(IEC 61000-4-5)