Overview of EOCRI3M420 Schneider Communication Intelligent Protector
EOCR-i3M420 概述
✔32-bit MCU+True RMS measurement, accuracy ± 1%
✔Protection functions: overload (OC), underload (UC), phase loss (PL), reverse phase (RP), imbalance (Ub), startup stall (Sc), running stall (JA), (optional) short circuit (SH)
✔Action time characteristics: timed limit, inverse time limit, thermal accumulation inverse time limit
✔THD total harmonic distortion monitoring: real-time monitoring of three-phase, adjustable alarm threshold
✔4~20mA analog output(Load)≤ 500 Ω, compatible with ModbusSimultaneously used)
✔Modbus RTU/RS-485 2400-38 400 bps remote communication
✔Display: Bar load graph+5-digit seven segment digital tube LED
Three phase current automatic rotation display/manual locking of a certain phase display (manual locking function)
✔Operation/Fault Records:
• Reasons for tripping and current records of the last 3 faults
Accumulated running time and timeout alarm records
• Limit the number of startup records
✔Fail Safe mode: independent start stop function (safe mode)
✔Password protection function: Three digit password to prevent accidental operation; Long term shutdown can restore factory settings
✔Reset mode: manual, automatic, power-off, remote communication
✔Structural selection: Terminal T, Bottom hole H, Window W
✔Three phase/single-phase mode Menu switchable
✔Compliance and certification: UL, CCC, compliant with EU RoHS
Overview of EOCRI3M420 Schneider Communication Intelligent Protector
EOCR-i3M420Specification Sheet
Basic Information | |
Manufacturer/Brand |
Schneider Electric |
Product Range (Series) |
EOCRseries |
Model Name |
EOCR-i3M420Digital motor protection relay (built-in display, integrated) |
place of origin |
Yishan Factory, South Korea |
Authorized General Agent in China |
Shanghai Hanshi Electric Automation Equipment Co., Ltd |
Protection function setting range | |
Protection setting range |
0.5~32 A(inverse time limit/heat accumulation inverse time limit), use external CT for 32A and above The external CT current range can be extended to 800 A |
Time Setting |
Overload protection OC: timed limit (0.2-30 seconds); Inverse time limit (1-30 classes) Underload protection UC: timed limit (0.5-30 seconds) Phase loss protection PL: 0.5 to 5 seconds (can be set to turn off) Reverse protection RP: Action time 0.15 seconds Unbalance protection Ub: action time 1-10 seconds, set range 10-50% Starting blockage Sc:+0.5 seconds after the start delay (D-Time) ends Running stall JA: 0.2 to 10 seconds |
Start delay D-Time |
0–200 s, closable |
Measurement and communication functions | |
Analog output |
4 – 20 mA (Load ≤ 500 Ω) |
communication interface |
Communication protocol: Modbus RTU Communication method: RS-485 Baud rate: 2400~38400 bps |
measurement accuracy |
± 1%, True RMS (32-bit MCU) |
THDmonitor |
Display when total harmonic distortion occurs, alarm threshold can be set |
Electrical parameter monitoring |
Real time display of three-phase current, alarm and action reasons |
Electrical and mechanical characteristics | |
Control power supply (Us) |
U:100–240 V AC/DC B:24 V AC/DC |
power frequency |
50/60 Hz |
Installation method |
35 mm DINGuide rail+panel screws |
output contact |
1NC + 1 NO (95-96/97-98)Overload trip (OL) |
Fuse specifications |
By 4 A gG |
Rated voltage of main circuit [Ue] |
600 V AC, 50-60 Hz (main circuit, UL compliant) 690 V AC, 50-60 Hz (main circuit, compliant with CSA) 690 V AC, 50-60 Hz (main circuit, compliant with IEC 60947-4-1) |
Impact withstand voltage (Uimp) |
6 kV(Complies with IEC 60947-4-1) |
reset method |
Manual reset (RESET) Automatic reset (0.5-1200 seconds) Electrical reset (power-off reset, 0-1 second) Communication remote reset (via Modbus communication) |
display interface |
Bar load chart+5-digit seven segment LED |
Relay power consumption |
3 W |
Ith /contact rating |
Ith 3 A;250 V AC 3 A |
Wiring specifications |
Control circuit cable: 2 × 1-1.5 mm ² (with/without terminal flexible cable M3) Control circuit cable: 1 × 1-2.5 mm ² (with/without terminal flexible cable M3) Main circuit terminal: 1 × 2.5-25 mm ² (flexible cable M6 without terminal) |
tightening torque |
Control circuit terminal: 0.8-1.2 N · m (cable diameter 4.7 mm) Main circuit terminal: 2.5 N · m (terminal clamp diameter 11 mm) |
External dimensions/weight |
WWindow type (W × H × D): 70 × 74.5 × 83.8 mm0.315 kg HBottom hole type (W × H × D): 70 × 56.3 × 108.1 mm0.355 kg TTerminal type (W × H × D): 70 × 91.3 × 108.1 mm0.473 kg |
environmental parameters | |
Protection level |
IP20(Complies with IEC 60529) |
Operating Temperature |
-20~60 ℃ (compliant with IEC 60947-4-1) |
Storage temperature |
-40~85℃ |
Using altitude |
2000 m |
flame retardancy |
650℃ (compliant with IEC 60695-2-12) |
impact resistance |
15 gn, 11 ms (compliant with IEC 60068-2-7) |
Vibration resistance |
Panel installation: 4 gn (IEC 60068-2-6) Rail installation: 2 gn (IEC 60068-2-6) |
insulation withstand voltage |
Between external and circuit: 2 kV (IEC 60255-5) Between mutual contacts: 1 kV (IEC 60255-5) Internal circuit: 2 kV (IEC 60255-5) |
surge resistance |
6 kV(IEC 61000-4-5) |