The vibration frequency meter is developed for measuring the working frequency of various machinery and equipment, which can measure the vibration frequency of general machinery and equipment, as well as equipment with high precision requirements. The instrument is composed of integrated circuits and high-sensitivity sensors, and has the characteristics of high reliability, low power consumption, and strong resistance. The instrument adopts an ABS handheld chassis and battery power supply, with LCD mode displaying frequency values and undervoltage, making operation simple and intuitive. The successful development of this instrument will greatly facilitate the on-site testing and calibration of machine equipment by testers.
ZYPLVibration frequency testertechnical indicators
1. Frequency range: 3.0Hz-10000.0Hz (-3dB)
The frequency range is determined by the user
2. Measurement range: 0.5-100g (acceleration)

4. Working power supply: 5 AA 1.5x5 batteries
5. Environmental conditions: working temperature 0 ℃ -50 ℃
6. Dimensions: 180 * 100 * 40mm
7. Weight: 430g
ZYPLVibration frequency testerInstructions
1. Vertically attach the magnetic suction seat at the bottom of the sensor to the device under test. When installing sensors, the surface of the base should be perpendicular to the vibration of the equipment. The sensor output line is connected to the host.
2. Turn the power switch to the "on" position, and it will be detected after 2 seconds.
3. When the "" indicator light on the display window is on, it indicates that the battery voltage is lower than the normal operating voltage, and the battery should be replaced in a timely manner (working current<10mA).

Precautions
1. Avoid hitting or knocking the sensor during use. The connection with the wire should not be twisted or pulled from the root.
2. The frequency range is also used for filtering. The frequency range is used to resist external interference, and appropriate upper and lower frequency values should be selected, otherwise there will be significant changes in the digital values of the frequency table.
3. Do not use gasoline or rubber water to clean the instrument.
4. When the instrument is not in use for a long time, remove the battery from the battery compartment behind the instrument to avoid battery damage.
5. When the instrument displays errors during the measurement process, consideration should be given to whether the battery is under voltage or whether the sensor is damaged.
Appendix:
1、 ZDY vibration measuring instrument is a digital display multifunctional vibration measuring instrument. This instrument is equipped with a piezoelectric accelerometer and a magnetic seat, which can easily measure the acceleration value (A), velocity value (V), and displacement amplitude value (M) of mechanical vibration, and the measurement results are all true effective value readings.
The instrument adopts an integrated design with a compact and reasonable structure. Powered by a 9V rechargeable battery. Touch the button switch. A 3.5-digit LCD display with a beautiful and elegant appearance makes it an ideal portable measuring instrument. This instrument is suitable for spot inspection, patrol inspection, and regular inspection of various equipment, and can conveniently monitor the status and diagnose faults of various mechanical equipment.
Main technical specifications of ZDY vibration measuring instrument:
1. Acceleration measurement range: 0-199.9 m/s2 (effective value)
2-3000 Hz (frequency response)
2. Speed measurement range: 0-199.9 mm/s (effective value)
5-1000 Hz (frequency response)
3. Displacement amplitude measurement range: 0-1999 um (peak to peak)
5-200 Hz (frequency response)
4. Measurement error range: ≤ 5%
5. Sensor type: piezoelectric accelerometer
6. Power supply method: 9V stacked battery
2、 The VT700/VT800 dynamic balance measuring instrument is aimed at domestic and foreign high-tech, using large-scale integrated circuit and microcontroller technology. This instrument has multifunctionality and can be used as both a tachometer and a vibration test. It can be used for both time-domain analysis and frequency-domain analysis. Especially with all the functions of measuring dynamic balance.
The instrument is easy to operate, with human-machine dialogue, menu prompts, and measurement data that can be locked and maintained at any time. The VT dynamic balancer has a compact and lightweight structure, with the keyboard and display screen on the panel, and input/output sockets and various control switches placed on the panel. The VT700 dynamic balancing instrument can perform on-site dynamic balancing of various rotating machinery,. Equivalent to a movable dynamic balancing machine. It is exquisitely designed and easy to carry, with the entire instrument housed in a portable instrument box.
Technical parameters of VT700 dynamic balance measuring instrument
1. General measurement:
Speed measurement: 30-30000 rpm
Ordinary vibration measurement: 0.1-5000 μ m (peak to peak)
0.1-2000mm/s (effective value)
Vibration analysis: FFT spectrum analysis
Display mode: Dot matrix graphic 64X240 Dot matrix graphic LCD Chinese dish
Keyboard: Eight keys
2. Dynamic balance measurement:
Measurement points: single measurement point or single-sided dual measurement point or double-sided
Same frequency working speed: 600-30000 rpm
Same frequency amplitude range: 0.1-5000 μ m (peak to peak)
Vibration intensity range: 0.1-2000mm/s (effective value)
Phase accuracy: 0-360 °± 1 °
Unbalance removal rate: ≥ 85%
Examples of Dynamic Balancing Operations
1Single plane balance
Enter dynamic balance measurement |
Single plane equilibrium |
1Selection: bandwidth, measurement method; Medium bandwidth, trial and error method |
2Preset speed: The default value is40000rpm;40000 rpm |
3Start the rotor to the equilibrium speed and press|execute|Start measuring with the key; |
|
4Display the measured values on the screen;1580rpm 64u269° |
|
5, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|key repeat4、5Two processes; |
6Brake rotor, add test weight;60g 90° |
7Start the rotor to the equilibrium speed for the second time and begin measuring; |
|
8Display the measured values on the screen;1580rpm 127u268° |
|
9, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|key repeat8、9Two processes; |
10Brake rotor; |
11Input the trial weight into the instrument;60g 90° |
12Remove the test weight or not; Remove the trial weight |
13The balance weight is displayed on the screen;61g 272° |
14Continue No, if continue, repeat7~10,13,14The process, otherwise it ends; |
2Double plane balance
Enter dynamic balance measurement |
Biplane equilibrium |
1Selection: bandwidth, measurement method; Medium bandwidth, trial and error method |
|
2Preset speed: The default value is40000rpm;40000 rpm |
3Start the rotor to the equilibrium speed and press|execute|Start measuring with the key; |
|
4Display on the screenAChannel measurement values;1580rpm 64u269° |
5, Press|maintain|Key, this value remains on the display screen. If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|Key repetition4、5Two processes; |
|
6Display on the screenBChannel measurement values;1580rpm 3.5u267° |
|
7, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|Key repetition6、7Two processes; |
8Brake rotor, inAFace test weight;60g 90° |
9Start the rotor to the equilibrium speed for the second time and begin measuring; |
|
10Display on the screenAChannel measurement values;1580rpm 105u268° |
|
11, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|Key repetition10、11Two processes; |
|
12Display on the screenBChannel measurement values;1580rpm 44u269° |
|
13, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|key repeat12、13Two processes; |
14Brake rotor, removeAInterview heavy, and inBFace test weight;60g 90° |
15Start the rotor to the equilibrium speed for the third time and begin measuring; |
|
16Display on the screenAChannel measurement values;1580rpm 67u268° |
|
17, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|key repeat16、17Two processes; |
|
18Display on the screenBChannel measurement values;1580rpm 69u 269° |
|
19, Press|maintain|Key, this value remains on the display screen, If satisfied, press|execute|Confirm this value with the key, otherwise press|maintain|key repeat18、19Two processes; |
20Brake rotor, removeBInterview heavy; |
|
21Input the trial weight into the instrument;Anoodles:60g 90° Bnoodles:60g 90° |
22Remove the test weight or not; Remove the trial weight |
|
23The balance weight is displayed on the screen;Anoodles:91.1g 273.6° Bnoodles:38.4g 257.5° |
24Continue No, if continue, repeat15~20,23,24The process, otherwise it ends; |