E-mail
671113565@qq.com
-
Phone
13761235453
-
Address
No. 265 East Street, Zhuangxing Town, Fengxian District, Shanghai
Shanghai Chengsi Intelligent Technology Co., Ltd
671113565@qq.com
13761235453
No. 265 East Street, Zhuangxing Town, Fengxian District, Shanghai
Dental module brushing and grinding testerDental module brushing and grinding tester
CSI-Z507 dental module brushing and grinding instrument
1、 Instrument Introduction:
Suitable for testing the cleaning rate of external color spots in toothpaste. Through experiments, it is possible to effectively compare and evaluate the relative cleaning rate of toothpaste for exogenous pigmentation, providing scientific basis for determining relevant technical indicators.
2、 Key parameters
Parameter items |
Specifications |
control system |
Industrial grade PLC |
operating interface |
Colorful 7-inch touch screen, switching between Chinese and English |
Operation method |
Full touch operation, capable of setting, calling, and modifying test programs |
printer |
Embedded printer |
Testing station |
9workbit |
Test count |
0time-99999 times |
test frequency |
0r/min-150r/Min (adjustable) |
Testing direction |
X. The Y-axis direction can be changed |
Vertical pressure |
150±2g Optional with other pressures |
security configuration |
Emergency stop button, overload protection |
power supply |
AC 220V/50Hz |
Overall dimensions |
about680*750*1100mm |
USB testing software socket, capable of reading data and connecting to a computer | |

3、 Execution standards and applicable scenarios
Compliant with standards:
GB/T43576-2023 Laboratory testing method for the effect of toothpaste on removing exogenous pigmentation in oral cleaning and care products - Batch quality inspection;
Third party laboratory certification.
4、 Example of Operation Process
Install the standard toothbrush and dental grinding block onto the grinding device, adjust the vertical pressure of the toothbrush on the dental block to 150g ± 2g, and then set the back and forth frequency of the grinding device to 100r/min. Add toothpaste slurry and control abrasive slurry to the slurry cups of the sample group and control group, respectively. Add an equal volume of slurry to each slurry cup to ensure that the slurry completely submerges the dental grinding block. Start the brush grinder,Round trip to and from the theater 600 times.
After brushing and grinding, remove the dental grinding block and rinse it with water three times until there is no visible tooth pulp residue. Dry the surface moisture with paper and measure the enamel whiteness value (L) within 10 minutes using a colorimeter.
Note: A new toothbrush needs to be replaced during each experiment. There may be sedimentation phenomenon in the few plate samples, and the dental pulp should be stirred during the process.
5、 Configuration List
1 host;
1 set of testing software;
1 copy of instruction manual;
1 certificate of conformity;
1 warranty card;
One copy of the delivery receipt;
1 nameplate;
1 power cord;
1 set of hexagonal wrench;
Several brochures;