Thermal conductivity tester - transient plane heat source method
CSI-L007 Transient Plane Heat Source Testing Machine、Multi functional rapid thermal conductivity tester、Thermal conductivity tester-Transient plane source method
1、 Description:
The instrument adopts the transient plane heat source method. Based on the transient plane heat source technology, the instrument tests the thermal conductivity, thermal conductivity coefficient (thermal diffusion coefficient), specific heat capacity, thermal storage coefficient and thermal resistance of solid, powder, liquid, paste, coating, film, thermal insulation material, thermal insulation material, anisotropic material and other materials: metal, alloy, graphite, thermal conductive silicone grease, silica gel, silicone rubber, ceramics, rock, polymer, paper, fabric, foam plastic, concrete, composite plate, paper honeycomb plate and so on.
2、 Execution standards
Standards: ISO 22007-2:2008, GB/T32064-2015
IIITechnical Specifications:
Control system: PLC+Windows system;
Operating interface: 12 inch embedded industrial computer in color, WiFi connection;
Wireless printing function,Using fully automated testing software to quickly and accurately analyze the parameters of the sample during the testing process and output reports;
Measurement range of thermal conductivity: 0.001-500 w/(m.k), with a resolution of 0.0001 w/(m.k);
Thermal diffusivity (thermal conductivity) range: 0.1-100 m2/s;
Range of thermal storage coefficient: 0.1-30 w/(m2. k);
Specific heat capacity range: 0.1-5 kJ/(kg. ℃);
Thermal resistance range: 0.5-0.000005 mm2/w;
Temperature measurement accuracy: ≤ 0.001 ℃;

Relative measurement error: ≤ 3%;
Repetitive error: ≤ 3%;
Test time: 1-120 seconds.
Temperature range of sample testing environment:optional-40~150℃; Standard configuration: Room temperature.
Probe configuration: Standard configuration: Diameter of Φ 15mm.
Optional probe diameter: 30mm, 15mm, 7.5mm;
Power supply: AC 220V ± 10%, 50/60 Hz;
Whole machine power: < 500w;
Standard external dimensions:L761*W500*H786mm;
Optional external dimensions: length 921, width 600, height 856.5mm
4Probe technical specifications:
1Heating material: nickel metal;
2Operating temperature: -50~150 ℃;
3Maximum power: 20W;
4、zuiHigh voltage: 20V;
5Maximum current: 1A;
6Resistance: around 10 Ω, according to the resistance value marked on the probe;
7Nickel wire specification: thickness 0.01mm, hot wire width: 0.35 ± 0.03mm;
8Hot wire spacing: 0.35 ± 0.03mm;
9Protective layer material: polyimide film; Single layer thickness: 0.06mm;
10Probe diameter: 30mm, 15mm, 7.5mm.
11The total thickness of the probe (including the thickness of the bonding layer) is 0.07 ± 0.02mm.